单选题A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?()AThe battery on the machine is bad.BThe root volume group is corrupted.CThe low-level debugger is not enabled.DThere is a problem with the CD-ROM.

单选题
A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?()
A

The battery on the machine is bad.

B

The root volume group is corrupted.

C

The low-level debugger is not enabled.

D

There is a problem with the CD-ROM.


参考解析

解析: 暂无解析

相关考题:

When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?() A. Establish a new theory of probable cause.B. Reverse the change.C. Implement the next logical change.D. Perform a root cause analysis.

A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?() A.The battery on the machine is bad.B.The root volume group is corrupted.C.The low-level debugger is not enabled.D.There is a problem with the CD-ROM.

The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()A.It is a hardware problem caused by the power failure.B.There is a network problem, most probably with name resolution.C.Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.D.Some filesets may be marked as broken and need to be reinstalled.

During a system administrator attempt to boot a server in normal mode, the boot process displays LED 299 and Led 201 and then stops. The LED 201 indicates that a ROS init or checkstop was detected. Which of the following options is the most probable cause?()A、A corrupted JFS log deviceB、A corrupted boot logical volumeC、An incorrect rc.boot entry in /etc/inittab fileD、A problem initializing paging space

Which of the following types of media would MOST likely cause above normal amounts of machine jamming?()A、EnvelopesB、Colored mediaC、LetterheadD、Pre punched

When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?()A、Establish a new theory of probable cause.B、Reverse the change.C、Implement the next logical change.D、Perform a root cause analysis.

A user is reporting a loud grinding sound when the machine is powered on. The machine loadsinto windows and the user does not notice any performance issues. Which of the following is the MOST likely cause of the noise?()A、PowersupplyfailureB、BadHDC、BadfanD、FaultyCD-Rom

Which of the following describes the FINAL step in the troubleshooting process?()A、Verify full system functionality.B、Implement the change.C、Test the theory to determine the cause.D、Root cause analysis.

After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()A、The cfgmgr command was not run to reconfigure the devicesB、The machine was not booted into SMS MultiBoot mode after configurationC、The machine was not in full system partition mode when the volume was createdD、The alt_disk_install command was not run with the -O option to remove references in the ODM

A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?()A、The battery on the machine is bad.B、The root volume group is corrupted.C、The low-level debugger is not enabled.D、There is a problem with the CD-ROM.

One of the mirrored disks for the root volume group has failed. Although the logical volumes are mirrored, and the bosboot command was run, the machine will not boot. What is the most probable cause?()A、Quorum was not turned offB、Paging space was not mirroredC、The dump space was not mirroredD、The surviving disk was too small

When using a mksysb and base media to clone a system, which of the following will cause the installation to fail()A、mksysb made on a single processor machine but is being installed on a multiple processor machine, no editing of the image.data fileB、mksysb made on machine with mirrored rootvg and new machine only has one disk in rootvg, no editing of the image.data fileC、mksysb made on a machine with 32GB of RAM but being installed on a machine with only 8GB of RAMD、mksysb made on a machine with virtual Ethernet adapter but being installed on a machine which only has a physical Ethernet adapter

A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()A、The ODM is corrupted.B、There is a hardware failure.C、The bosboot command failed.D、Not enough space is available in the filesystems.

A system administrator boots a server in normal mode, the boot process displays and LED 551 and stops. LED 551 indicates the root volume group is being varied on. All of the following are probable causes of the problem EXCEPT:()A、The bosboot command failed to complete.B、The JFS log device is corrupted.C、The initttab file is corrupted.D、The /dev entries or /etc files are missing.

A technician is booting up a computer but the computer never moves beyond POST. The floppydisk drive light stays lit continuously during the boot process. Which of the following is the MOST likely cause?()A、The hard drive is not formatted.B、The BIOS is corrupted.C、The motherboard has faulty capacitors.D、The drive cable is backwards

单选题A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?()AThe battery on the machine is bad.BThe root volume group is corrupted.CThe low-level debugger is not enabled.DThere is a problem with the CD-ROM.

单选题When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?()A Establish a new theory of probable cause.B Reverse the change.C Implement the next logical change.D Perform a root cause analysis.

单选题The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()AIt is a hardware problem caused by the power failure.BThere is a network problem, most probably with name resolution.CSine the system was never rebooted, devices are marked defined instead of available and need to be activated.DSome filesets may be marked as broken and need to be reinstalled.

单选题One of the mirrored disks for the root volume group has failed. Although the logical volumes are mirrored, and the bosboot command was run, the machine will not boot. What is the most probable cause?()AQuorum was not turned offBPaging space was not mirroredCThe dump space was not mirroredDThe surviving disk was too small

单选题When using a mksysb and base media to clone a system, which of the following will cause the installation to fail()Amksysb made on a single processor machine but is being installed on a multiple processor machine, no editing of the image.data fileBmksysb made on machine with mirrored rootvg and new machine only has one disk in rootvg, no editing of the image.data fileCmksysb made on a machine with 32GB of RAM but being installed on a machine with only 8GB of RAMDmksysb made on a machine with virtual Ethernet adapter but being installed on a machine which only has a physical Ethernet adapter

单选题A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()AThe ODM is corrupted.BThere is a hardware failure.CThe bosboot command failed.DNot enough space is available in the filesystems.

单选题After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()AThe cfgmgr command was not run to reconfigure the devicesBThe machine was not booted into SMS MultiBoot mode after configurationCThe machine was not in full system partition mode when the volume was createdDThe alt_disk_install command was not run with the -O option to remove references in the ODM

单选题Which of the following describes the FINAL step in the troubleshooting process?()A Verify full system functionality.B Implement the change.C Test the theory to determine the cause.D Root cause analysis.

单选题When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?()AEstablish a new theory of probable cause.BReverse the change.CImplement the next logical change.DPerform a root cause analysis.

单选题Which of the following types of media would MOST likely cause above normal amounts of machine jamming?()AEnvelopesBColored mediaCLetterheadDPre punched

单选题A section of the building has been having intermittent connectivity problems lately. An action plan and solution has been created. Which of the following steps would an administrator perform NEXT?()ADocument the solution and process.BEstablish the most probable cause.CImplement and test the solution.DIdentify additional symptoms and problems

单选题During a system administrator attempt to boot a server in normal mode, the boot process displays LED 299 and Led 201 and then stops. The LED 201 indicates that a ROS init or checkstop was detected. Which of the following options is the most probable cause?()AA corrupted JFS log deviceBA corrupted boot logical volumeCAn incorrect rc.boot entry in /etc/inittab fileDA problem initializing paging space

单选题A user is reporting a loud grinding sound when the machine is powered on. The machine loadsinto windows and the user does not notice any performance issues. Which of the following is the MOST likely cause of the noise?()APowersupplyfailureBBadHDCBadfanDFaultyCD-Rom