单选题The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.Amain stem stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve

单选题
The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.
A

main stem stop valve

B

auxiliary steam stop valve

C

feed check or control valve

D

blow down valve


参考解析

解析: 暂无解析

相关考题:

The deck control valve to be ______ after being repaired.A.returned and attached againB.moved and fitted againC.removed and refittedD.reproduced and put on again

The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a flame ______.A.stopperB.screenC.filterD.restrictor

Valves on steam-smothering lines to cargo tanks shall be set with ______.A.The master control valve shut and valves to individual cargo tanks shutB.The master control valve open and valves to individual cargo tanks shutC.The master control valve shut and valves to individual cargo tanks openD.All valves open

If the hatch cover does not move, ()should be checked.A、the open valveB、the stop valveC、the steam valveD、the close valve

单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()Acold fuel oilBlow fuel oil pressureClow atomizing steam pressureDwater in the fuel oil

单选题A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a().Aflame stopperBflame screenCflame filterDflame restrictor

单选题The deck control valve to be()after being repaired.Amoved and fitted againBremoved and refittedCreproduced and put on againDreturned and attached again

单选题The() is fitted in pair one is the main valve, the other the auxiliary or standby.Amain stem stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve

单选题A gypsy or gypsyhead is a().Apunt used for painting over the sideBsmall, reciprocating steam engineCspool-shaped drum fitted on a winchDswinging derrick

单选题Between the steam dram and the smaller water dram below, large numbers of smaller diameter () tubes are fitted.AfireBwater wallCgeneratingDdown comer

单选题If the hatch cover does not move, ()should be checked.Athe open valveBthe stop valveCthe steam valveDthe close valve

单选题In an auxiliary boiler steam and water system, the highest pressure will be in the ().Asteam stop valveBdry pipeCfeedwater systemDgenerating tubes

单选题To assist separation of low viscosity oils steam coils or electric heaters are fitted () of the oily water separator.Ain entranceBin exitCin the upper partDon the outside

单选题Fire protection regulations for towing vessels require any fuel line subject to internal head pressure from fuel in the tank to().Abe fitted with a positive fuel shut-off valve located at the tankBhave a shut-off valve at the top of the tankChave a gate valve easily accessible in the space where the tank is locatedDhave a drain cock at the lowest point in the fuel line

单选题Large pipes or () are fitted between the steam and water drums to ensure good natural circulation of water.Afire-tubesBfurnacesCdown-comersDsoot-blowers

单选题The()is fitted in the main steam supply line and is usually of the non-return type.Amain steam stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve

单选题Excessive valve lash in an auxiliary diesel engine will cause the valves to open()Alater and close soonerBsooner and close laterCsooner and close soonerDlater and close later

单选题The() is a smaller valve fitted in the auxiliary steam supply line, and is usually of the non-return type.Amain stem stop valveBauxiliary steam stop valveCfeed check or control valveDblow down valve

单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts

单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain

单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()Acarbon deposits on the flame scannerBhigh fuel oil temperatureClow fuel oil viscosityDhigh steam pressure

单选题A feed pump for an auxiliary boiler might lose suction if the ().Aboiler water level is lowBfeedwater is too hotCboiler steam demand is lowDfeedwater is too cold

单选题The water level in a steaming auxiliary boiler will always ()Arise when the steam pressure is increasedBremain constant as long as the feed pump operatesCfall when the steam pressure is decreasedDvary as the steam demand changes

单选题A butterfly valve consists basically of a disc pivoted across the bore of a ring body having the same radial dimensions as the pipe in which it is fitted.According to the above sentence, which of the following statements is not true?()AThe diameter of a disc is the same as the outer diameter of the pipeBWe can infer that the valve is opened or closed by rotating the spindleCA butterfly valve comprises a disc and a ring bodyDThe profile of the butterfly valve is a ring body

单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().Acheck and regulate the water levelBclose the air cock once fires are litCblowdown the gage glassDcrack the steam stop to assure protective steam flow

单选题A device fitted over the discharge opening on a relief valve consisting of one or two woven wire fabrics is called a flame().AstopperBscreenCfilterDrestrictor