The HMC software has just been upgraded remotely via the WebSM client. It now needs to be rebooted to make the update active. How can this be accomplished?()A、Use ssh to connect to the HMC and rebootB、The upgrade will display complete and ask you to rebootC、Select shutdown in the Management section of the WebSM clientD、Once logged out of the WebSM client it will ask to logoff, shutdown or reboot. Select reboot.

The HMC software has just been upgraded remotely via the WebSM client. It now needs to be rebooted to make the update active. How can this be accomplished?()

  • A、Use ssh to connect to the HMC and reboot
  • B、The upgrade will display complete and ask you to reboot
  • C、Select shutdown in the Management section of the WebSM client
  • D、Once logged out of the WebSM client it will ask to logoff, shutdown or reboot. Select reboot.

相关考题:

WhichofthefollowingcandeploysystemplansgeneratedbytheIBMSystemPlanningTool(SPT)?() A.TheHardwareManagementConsole(HMC)andIntegratedVirtualizationManager(IVM).B.TheHardwareManagementConsole(HMC)andAdvancedSystemManagerInterface(ASMI).C.IntegratedVirtualizationManager(IVM)andAdvancedSystemManagerInterface(ASMI).D.IntegratedVirtualizationManager(IVM)andBladeCenterAdvancedManagementModule(AMM).

An administrator has an existing HMC and POWER6 570 connected to a network switch. The administrator is planning to install two POWER6 570s with a dedicated HMC.Which infrastructure is required for the new HMC?()A.An additional switch for the new HMCB.Asynchronous adapters on the new HMCC.The two 570 servers are directly connected to the new HMCD.One 570 is directly connected to the new HMC and the other is directly connected to the existing HMC

WhichoneofthesestatementsistrueregardinghotpluggablePCIeandPCI-XslotsinaPower550?() A.CardscanbeaddedandthenenabledviaHardwareManagementConsole(HMC)GUIorcommandline.B.TheHMCallowsaccesstotheAdvancedSystemManagementInterface(ASMI),wheretheslotscanbemanaged.C.IftheemptyslotwasalreadyallocatedtoanLPAR,theLPARcanusethecardafterthecfgmgrscripthasbeenrun.D.TheHardwareManagementConsole(HMC)GUIcanguideacustomerthroughtheprocessofaddingacardtoanemptyslot.

下面那些代码是普力马的车型代码()A、HMC7160B3S0B、HMC6433EC、HMC7162AD、HMC6434A3M0E、HMC7180F、HMC7186B3/4

An administrator has an existing HMC and POWER6 570 connected to a network switch.  The administrator is planning to install two POWER6 570s with a dedicated HMC. Which infrastructure is required for the new HMC?()A、An additional switch for the new HMc  B、Asynchronous adapters on the new HMcC、The two 570 servers are directly connected to the new HMc  D、One 570 is directly connected to the new HMC and the other is directly connected to the existing HMc

A pSeries technical specialist is performing a solutions assurance with a customer for a new single-frame 10-node p655 system being attached to a currently installed HMC.  Which of the following questions should be asked to gather all the required information to determine whether the p655 solution can connect to the HMC?()A、Are there at least ten RS-232 ports available on the HMC?B、Are there at least ten RS-422 ports available on the HMC?C、Are there at least ten RS-232 and two RS-422 ports available on the HMC?D、Are there at least two RS-232 and ten RS-422 ports available on the HMC?

A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A、 To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B、 Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C、 Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD、 Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from

下面那些代码是丘比特的车型代码()A、HMC7151A4H0B、HMC7161C、HMC7163D、HMC7132A4H0E、HMC7133A4H0F、HMC7160B3S0

The customer intends to install a 7315-CR2 into a p690 frame.  What should the pSeries technical specialist tell the customer?()A、The HMC is a 19" form factor.B、The HMC is a 24" form factor.C、The HMC requires a 100-120 volt power connection.D、The HMC requires a 200-240 volt power connection.

Companycom is installing a p5 595 with AIX 5.3. The DLPAR option for the resources cannot be selected on the HMC menus. However, the daemons are running on both the HMC and LPARs. Which of the following is a prerequisite for DLPAR functionality?()A、The resources must be unallocated in an LPARB、The microcode on the pSeries must be currentC、All network adapters on the LPAR must be definedD、Network connectivity and name resolution capability between HMC and LPARs

An administrator needs to recover an HMC due to a failed disk. The disk has been replaced, allowing the administrator to reinstall the HMC back to the required release of software. Backups of both the HMC Console Data and Upgrade Data are available. After reloading the HMC with the Recovery DVDs, what are the next steps to restore the HMC configuration?()A、Use the 'HMC Management Restore HMC Data' option to first restore just the HMC Data..B、Use the 'HMC Management Restore Upgrade Data' option to first restore just the Upgrade Data.C、Use the 'HMC Management Restore HMC Data' option to first restore the HMC Data and then the Upgrade Data.D、Use the 'HMC Management Restore Upgrade Data' option to first restore the Upgrade Data, and then the HMC Data.

Companycom has several CR3 HMCs managing their p690 servers. They have purchased a new p5 570 and would like to manage the new system with an existing HMC. What is required to support this environment?()A、Free up one HMC and update the software for use with the p5 570B、Connect the new p5 570 server to an existing HMC and manage the p690s and p5 570 from that HMCC、Order a new HMC to support the new p5 570 server since the CR3 HMC is not supported for a p5 570D、Backup the HMC to DVD-RAM and select HMC migrate to move all the profile data to the new HMC software

Companycom currently has three p650 servers in their environment and they are implementing a p5 595. The p650 servers are running in an SMP environment, but are connected to a pair of HMCs. In order to follow best practices in the enterprise server environment and maintain HMC connectivity to the p650s, what else will needs to be ordered in addition to the p5 595?()A、Include a new HMC in the order to connect to the p5 595B、Include a pair of new HMCs in the order to connect to the p5 595C、Include a media set for POWER5 HMC in the order to upgrade one of the existing HMC’s to POWER5 capabilitiesD、Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC to POWER5 capabilities Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC? To POWER5 capabilities

A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()A、Purchase a second HMC and use this to manage the new servers.B、Connect all of the new servers to the existing private HMC network.C、Configure a second private network on their existing HMC for the new servers.D、Connect 9 of the new servers to the existing HMC and use Integrated Virtualization Manager on the 10th.

On which HMC GUI panel can the ’Enable Electronic Service Agent’ option be found?() A、HMC ManagementB、Systems ManagementC、Service ManagementD、Electronic Management

The IP address of POWER6 595 is showing up in the HMC instead of the server name. Next to the IP address is the status, which shows ailedThe IP address of POWER6 595 is showing up in the HMC instead of the server name. Next to the IP address is the status, which shows ailed Authentication The system administrator needs to enter a password. Which password is needed to restore connection for the POWER6 595 to the HMC?()  A、The hscroot user password.B、The CE password.C、The HMC password.D、The ASM admin password.

A client has an existing p5 570 that is directly connected to a HMC. The customer will be purchasing another p5 570. Which of the following solutions would be appropriate to provide HMC connectivity to the second p5 570?()A、Implement a proxy server to provide multiple sources to one destination B、Purchase an additional Ethernet adapter for each p5 570 to provide connectivity between the two C、Purchase a network hub or switch so both p5 570s can connect to the single HMC D、Purchase an additional HMC since multiple HMC are required when more than one POWER5 Enterprise class server is used Purchase an additional HMC since multiple HMC? are required when more than one POWER5 Enterprise class server is used

A customer currently has five partitioned POWER4 systems and is adding new systems.  When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()A、Order a new HMC to support the p5 system.B、Attach the new p5 system to the existing HMC.C、Upgrade the existing HMC to accommodate both the POWER4 and p5 systems.D、Do nothing.  This system does not require an HMC.

Company.com has encountered a problem on the HMC, which requires access to the root shell on the HMC. Which of the following is necessary to access the root userid on the HMC?()A、Enable remote commands on the HMC Configuration menu,then use ssh to login to theHMC,enter su - rootB、Login to the HMC as hscpe and run pesh,using a temporary password from IBM Support,afterward, enter su - rootC、Login to the HMC as hscroot,then run pesh,using a temporary password from IBM Support, afterward,enter su - rootD、Enable remote commands on the HMC Configuration menu,then telnet in as hscroot,entersu - root

A system administrator wants to control the HMC from their workstation. Microsoft Windows 2000 is running and the HMC graphical user interface is being used remotely. Which of the following actions will accomplish this task?()A、Use any Windows 2000 to graphically access the HMCB、Load, install, and configure WebSM on the workstationC、Telnet to the HMC using Exceed or a GUI emulator product from the workstationD、Load, install, and configure OpenSSH or SSH on the workstation and access the HMC through the GUI interface

Which of the following should be done FIRST when setting up a new p5-520 to be managed by a new HMC via a private network?()A、Change passwords in ASMIB、Add the managed system to the HMCC、Connect the p5-520 to a power sourceD、Connect the HMC and the p5-520 server’s HMC1 port to the same network

单选题A pSeries technical specialist is performing a solutions assurance with a customer for a new single-frame 10-node p655 system being attached to a currently installed HMC.  Which of the following questions should be asked to gather all the required information to determine whether the p655 solution can connect to the HMC?()AAre there at least ten RS-232 ports available on the HMC?BAre there at least ten RS-422 ports available on the HMC?CAre there at least ten RS-232 and two RS-422 ports available on the HMC?DAre there at least two RS-232 and ten RS-422 ports available on the HMC?

单选题An administrator has an existing HMC and POWER6 570 connected to a network switch.  The administrator is planning to install two POWER6 570s with a dedicated HMC. Which infrastructure is required for the new HMC?()AAn additional switch for the new HMc  BAsynchronous adapters on the new HMcCThe two 570 servers are directly connected to the new HMc  DOne 570 is directly connected to the new HMC and the other is directly connected to the existing HMc

单选题In order for DLPAR operations to be possible, the RMC daemons on the Hardware Management Console (HMC) must communicate with the RMC daemons on all of the LPARs involved. How can the RMC daemons be restarted on the HMC, causing the least disruption?()ARun /usr/sbin/rsct/bin/rmcctrl z as hscroot. BReboot the HMC, either through the GUI or via the command line. CDisable and re-enable RMC in the Firewall settings in the HMC GUI. DSelect the Partition Communication checkbox in the LAN Adapter dialogue box.

单选题A new p5 customer has just installed a partitioned p5-550 alongside some older POWER4 servers.  The pSeries technical specialist has received a call to say that the existing HMC (7315) cannot connect to the new server.  How can the specialist help the customer?()AExplain to the customer that they need an additional HMC for the POWER5 system.BObtain a PO from the customer to purchase additional serial connections to the HMC.CObtain a PO from the customer to purchase additional Ethernet connections to the HMC.DExplain to the customer that they need a firmware update on the HMC to support both POWER4 and POWER5.

单选题An administrator has an existing HMC and POWER6 570 connected to a network switch. The administrator is planning to install two POWER6 570s with a dedicated HMC. Which infrastructure is required for the new HMC?()AAn additional switch for the new HMCBAsynchronous adapters on the new HMCCThe two 570 servers are directly connected to the new HMCDOne 570 is directly connected to the new HMC and the other is directly connected to the existing HMC

单选题The customer intends to install a 7315-CR2 into a p690 frame.  What should the pSeries technical specialist tell the customer?()AThe HMC is a 19 form factor.BThe HMC is a 24 form factor.CThe HMC requires a 100-120 volt power connection.DThe HMC requires a 200-240 volt power connection.

单选题A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from