An administrator has recently added a VLAN to the VIO server and wants to update the documentation.  Which command displays the current VIO server VLAN configuration?()  A、lsmap -allB、lsmap -netC、lsmap -entD、lsmap -vlan

An administrator has recently added a VLAN to the VIO server and wants to update the documentation.  Which command displays the current VIO server VLAN configuration?()  

  • A、lsmap -all
  • B、lsmap -net
  • C、lsmap -ent
  • D、lsmap -vlan

相关考题:

AnadministratorwantstorecorddetailsofalllogicalvolumesmappedasvirtualdisksonaVIOserverpartitionandtheassociatedvirtualtargetdevicesandmappings.WhichIOScommandcantheadministratorusetoachievethis?() A.lssp-detailB.lsvdev-svtd-clvC.lsmap-typelv-allD.lsdev-Csvirtual-tlv

AclienthastheneedtorebootoneoftheirVirtualIOServers.Whatcommand(s)wouldberuntolisttheclientsthataredependantonVirtualIOServerdiskandnetworkresources?() A.lsmap-all-netB.lsclient-disk-netC.lsdev-virtual-clientD.lsmap-all;lsmap-net

AnadministratorhasrecentlyaddedaVLANtotheVIOserverandwantstoupdatethedocumentation.WhichcommanddisplaysthecurrentVIOserverVLANconfiguration?() A.lsmap-allB.lsmap-netC.lsmap-entD.lsmap-vlan

VLAN 3 is not yet configured on your switch.What happens if you set the switchport access vlan 3 commmand interface configuration mode?() A.The command isaccepted and the respective VLAN is added to vlan dat.B.The command isrejected.C.The command isaccepted and you must configure the VLAN manually.D.The port turns amber.

The administrator wants to backup the existing VIO server software and its current configuration before applying an update.  What command will the administrator use to backup the VIO server software so that the backup can be restored from a Network Installation Manager (NIM) server or a Hardware Management Console (HMC)?()A、 mksysb -t vio /mountpointB、 backupios -file /mountpointC、 mksysb -i /mountpoint/vio.mksysbD、 backupios -mksysb -file /mountpoint/vio.mksysb

A VTP domain has six active VLANs. Without notice, all VLANs except VLAN1 fail. Just prior tothe failure, Switch2 was added to the network. Which three issues on Switch2 could be the cause?()A、Switch2 is configured for only VLAN1B、Switch2 is a VTP server in a different domainC、Switch2 is a VTP server in the Company domainD、Switch2 is not a VTP domain.E、Switch2 has a lower VTP configuration revision number than the current VTP revisionF、Switch2 has a higher VTP configuration revision number than the current VTP revision

Which statement best describes what is depicted in the show command output?()A、 IGMP snooping is not active for VLAN 120 because the IGMP feature has not been enabled on the switch with the feature igmp command.B、 The IGMP snooping querier for VLAN 120 is not in a running state because the Loopback interface configured with 1.1.1.1/32 is currently in a down state.C、 IGMP snooping has been disabled on the VLAN 120 SVI.D、 IGMP snooping has been disabled for VLAN 120 in VLAN configuration mode.E、 IGMP snooping is not active for VLAN 120 because VLAN 120 does not exist in the VLAN database.

VLAN 3 is not yet configured on your switch.What happens if you set the switchport access vlan 3 commmand interface configuration mode?()A、The command is accepted and the respective VLAN is added to vlan dat.B、The command is rejected.C、The command is accepted and you must configure the VLAN manually.D、The port turns amber.

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()A、lsmap -allB、lsmap -netC、lsmap -entD、lsmap -vlan

Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers.  Which of the following commands will identify the Shared Ethernet Adapter mapping?()A、ifconfig -aB、netstat -nrC、lsmap -all -netD、lsdev -Cc adapter

An administrator has a requirement to mirror the operating system on a VIO server. Which of the following IOS commands will achieve this?()A、 mirrorvgB、 iosmirrorC、 mirroriosD、 mkiosmirror

Which action enables an administrator to make a VIO Server automatically activate when the physical machine is powered on?()  A、Ensure the /etc/auto_start file exists on the VIosB、Ensure the ’cfgdev -a boot=yes’ command has been executed.C、Select the ’Automatically start when the managed system is powered on’ option within the vio Server lpar profile.D、Add the VIO Server to the ’Automatically start when the managed system is powered on’ field on the managed System properties.

A client has the need to reboot one of their Virtual IO Servers. What command(s) would be run to list the clients that are dependant on Virtual IO Server disk and network resources?()A、lsmap -all -netB、lsclient -disk -netC、lsdev -virtual -clientD、lsmap -all; lsmap -net

An administrator wants to record details of all logical volumes mapped as virtual disks on a VIO server partition and the associated virtual target devices and mappings.  Which IOS command can the administrator use to achieve this?()A、 lssp -detailB、 lsvdev -s vtd -c lvC、 lsmap -type lv -allD、 lsdev -Cs virtual -t lv

Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()A、Shut down all client partitions before updating the VIO server.B、Disconnect the client partitions from any IP networks before updating the VIO server.C、Update the client partitions to the latest OS maintenance level before updating the VIO Server.D、Update the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.

Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()A、Use DLPAR to avoid an outage.B、Deploy a redundant VIO server in the POWER5 system.C、Add additional Host Bus Adapters and Network adapters to the VIO server.D、Implement a standby server and move all partitions to it before applying future updates.

An administrator is trying to diagnose as to why a new VIO client (vio_client1) cannot see an allocated disk (hdisk4) from a VIO server (VIOS-A). The client virtual SCSI adapter has a slot ID of 5 and the corresponding VIO server virtual SCSI adapter has a slot ID of 3. The administrator checks the virtual SCSI configuration from the HMC using the following lshwres command.  lshwres –r virtualio --rsubtype scsi -m 9117-570*65ABCDE  --level lpar -F / lpar_name,slot_num,remote_lpar_name,remote_slot_num,backing_device VIOS A,5,vio_client2,2,hdisk3 VIOS-A,4,vio_client1,4,hdisk4 VIOS-A,3,vio_client1,6,hdisk5 VIOS-A,2,vio_client3,2,hdisk6 vio_client2,2,VIOS-A,5,hdisk0 vio_client1,4,VIOS-A,4,hdisk0  vio_client1,5,VIOS-A,3,null vio_client3,2,VIOS-A,2,hdisk0 From the output above,  what is the most likely reason why the client cannot see the mapped storage?()A、 The hard disk has been inccorectly mapped on the VIO server.B、 The hard disk has been incorrectly addressed on the VIO client.C、 The client SCSI adapter has been mapped to the incorrect server SCSI adapter.D、 The server SCSI adapter has been mapped to the incorrect client server adapter.

A user has an application server LPAR with a physical Ethernet adapter. They want to have a database LPAR also connected to the application LPAR via virtual Ethernet. Their security policies require a firewall between the application LPAR and database LPAR. Which of the following virtual Ethernet configurations satisfies the customer’s requirements?()A、The application server,firewall,and database server on the same VLANB、The application server and firewall on one VLAN,and the database server on a second VLANC、The application server on one VLAN,and the database server and firewall on a second VLAND、The application server and firewall on one VLAN,and the firewall and database server on a second VLAN

单选题Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO  server. Which of the following procedures should be taken to maintain the integrity of the partitions?()AShut down all client partitions before updating the VIO server.BDisconnect the client partitions from any IP networks before updating the VIO server.CUpdate the client partitions to the latest OS maintenance level before updating the VIO Server.DUpdate the VIO server while the partitions are running, but reboot each client partition at a convenient time after the update.

单选题A client has the need to reboot one of their Virtual IO Servers. What command(s) would be run to list the clients that are dependant on Virtual IO Server disk and network resources?()Alsmap -all -netBlsclient -disk -netClsdev -virtual -clientDlsmap -all; lsmap -net

单选题An administrator wants to record details of all logical volumes mapped as virtual disks on a VIO server partition and the associated virtual target devices and mappings.  Which IOS command can the administrator use to achieve this?()A lssp -detailB lsvdev -s vtd -c lvC lsmap -type lv -allD lsdev -Cs virtual -t lv

单选题An administrator has recently added a VLAN to the VIO server and wants to update the documentation.  Which command displays the current VIO server VLAN configuration?()Alsmap -allBlsmap -netClsmap -entDlsmap -vlan

单选题An administrator has a requirement to mirror the operating system on a VIO server. Which of the following IOS commands will achieve this?()A mirrorvgB iosmirrorC mirroriosD mkiosmirror

单选题An administrator has recently added a VLAN to the VIO server and wants to update the documentation. Which command displays the current VIO server VLAN configuration?()Alsmap -allBlsmap -netClsmap -entDlsmap -vlan

多选题A VTP domain has six active VLANs. Without notice, all VLANs except VLAN1 fail. Just prior tothe failure, Switch2 was added to the network. Which three issues on Switch2 could be the cause?()ASwitch2 is configured for only VLAN1BSwitch2 is a VTP server in a different domainCSwitch2 is a VTP server in the Company domainDSwitch2 is not a VTP domain.ESwitch2 has a lower VTP configuration revision number than the current VTP revisionFSwitch2 has a higher VTP configuration revision number than the current VTP revision

单选题Which statement best describes what is depicted in the show command output?()A IGMP snooping is not active for VLAN 120 because the IGMP feature has not been enabled on the switch with the feature igmp command.B The IGMP snooping querier for VLAN 120 is not in a running state because the Loopback interface configured with 1.1.1.1/32 is currently in a down state.C IGMP snooping has been disabled on the VLAN 120 SVI.D IGMP snooping has been disabled for VLAN 120 in VLAN configuration mode.E IGMP snooping is not active for VLAN 120 because VLAN 120 does not exist in the VLAN database.