单选题Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()AUse lquerypv to read the driveBUse lspv and look at PP Size valueCLook on the outside of the drive itselfDUse bootinfo to find the LTG on the drive

单选题
Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()
A

Use lquerypv to read the drive

B

Use lspv and look at PP Size value

C

Look on the outside of the drive itself

D

Use bootinfo to find the LTG on the drive


参考解析

解析: 暂无解析

相关考题:

Companycom has a p690 and currently has eight LPARs. They have purchased a p5 590 and wish to migrate their eight LPARs to the new server. The LPARs are running either AIX 5.2 or AIX 5.3 with the current maintenance. What is the LEAST disruptive method for this activity?()A、New install of AIXB、Migrate the 7040-61DC、Utilize alt_disk_installD、Use the enterprise back up strategy

Companycom wants to apply a PTF to the p5 590 system. After doing a preview install, the output shows there is insufficient space in the /usr filesystem. The root volume group has no available physical partitions left. They do not want to add additional disk drives to the system, but have a jfs2 filesystem that is only 8% used. What could they do to utilize space in the jfs2 filesystem to apply this PTF?()A、Backup the filesystem and recreate smallerB、Use the chfs to reduce the filesystem sizeC、Use cplv to copy filesystem to smaller sizeD、Use migratepv to copy filesystem to smaller size

A current Sun Solaris customer has just purchased their first p5 590. During the Solution Assurance, the backup requirements were discussed. Which of the following should be recommended to the customer with regards to restoring rootvg?()A、mksysbB、restvgC、AIX install CDsD、Veritas NetBackup

A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer.  From which of the following locations can the new storage drives be added?()A、 Format commandB、 HypervisorC、 Computer ManagementD、 Disk ManagementE、 Virtual Center

A customer has an 8-way p5-570 with eight internal disk drives and AIX 5.2.  Which of the following must be added, if anything, to the configuration to support four LPARs, assuming each LPAR requires twodisk drives?()A、7311-D20 drawer with four disksB、Upgrade to AIX 5.3C、Fiber adapters to attach to SAND、Nothing

An administrator has a two-disk volume group (testvg) with one logical volume (testlv) which has just  been mirrored across both disk drives.  Which of the following commands can be used to turn off quorum()A、chvg -Qn testvgB、chlv -Qn testvgC、varyoffvg testvg; varyonvg -Qn testvgD、varyoffvg testvg; exportvg testvg; importvg -Qn testvg; varyonvg testvg

Companycom is considering a partitioned solution which will require cumulative rPerf total of 150. The original sizing came back recommending a 32-way p5 590. However, they have a requirement for future scalability and availability is important. Which of the following would be the best reason to recommend a p5 595?()A、The p5 595 would allow for CODB、The p5 595 includes the Advanced Power Virtualization hardware and softwareC、The p5 595 is priced the same as the p5 590 given the same number/type of CPUsD、The p5 595 performance would be equivalent to the p5 590 given the same number/type of CPUs

Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()A、Use lquerypv to read the driveB、Use lspv and look at PP Size valueC、Look on the outside of the drive itselfD、Use bootinfo to find the LTG on the drive

Companycom has several CR3 HMCs managing their p690 servers. They have purchased a new p5 570 and would like to manage the new system with an existing HMC. What is required to support this environment?()A、Free up one HMC and update the software for use with the p5 570B、Connect the new p5 570 server to an existing HMC and manage the p690s and p5 570 from that HMCC、Order a new HMC to support the new p5 570 server since the CR3 HMC is not supported for a p5 570D、Backup the HMC to DVD-RAM and select HMC migrate to move all the profile data to the new HMC software

Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()A、POWER5 runs in an SMP mode as defaultB、POWER5 can run in a full system mode the same as the p690C、POWER5 can run in full system mode with the purchase of PLMD、POWER5 can run in a full system mode, but it is in LPAR mode

A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()A、A CD or DVD with installation mediaB、An internal SCSI adapter in the target LPARC、An Ethernet adapter for access to an FTP serverD、Advanced Power Virtualization feature of the p5 590

Companycom has a Linux LPAR on a p5 570 server. The 3rd party storage subsystem devices are not supported by Linux. How would access be provided to the storage subsystem devices for this Linux LPAR?()A、Daisy chain the unsupported 3rd party storage subsystem devices with the local SCSI disk drive B、Assuming the 3rd party storage subsystem has AIX support, enable access through a Virtual IO Server C、Assuming the 3rd party storage subsystem has AIX support, implement the Linux partition within an AIX partition D、3rd party storage is not an option for p5 570 servers and therefore only IBM disk subsystems can be considered as a solution

Companycom has just installed a p5 595 with four uncapped LPARs in a shared processor pool. The system and profile settings are still in their default states. One of the LPARs has an application that is consuming all of the available shared processor resources. Users of this application are complaining about response time. Which of the following changes to the slow LPAR would improve response time?()A、Enable SMTB、Reduce the weightC、Renice the processD、Increase the weight

The customer has an older storage array and is looking to migrate data that currently exists onover 100 73 GB FC drives to a new IBM System Storage DS5020. The customer states that theyhave only 3 TB of data and wants to consolidate on to fewer higher capacity drives. There are sixapplication servers running multiple applications and operating systems utilizing the storagesystem. What would be the next step to accurately identify the new storage configuration?()A、initiate a Disk Magic studyB、initiate a Capacity Magic studyC、runiometer on the current environmentD、utilize the IBM Disk capacity planner toolkit

Error log analysis indicates that a disk is starting to fail and will need to be replaced. The failing disk contains multiple logical volumes which span multiple disks. A free disk has been added to the failing disk’s volume group.Which of the following is the most efficient method to move the data from the failing disk to the new disk?()A、Back up the data, remove the failing disk from the volume group, then restore the data to the new disk.B、Use the migratepv command to move data from one disk to another and then remove the failing disk from the volume group.C、Use the mirrorvg command to mirror the data to the new disk, break the mirror and then remove the failing disk from the volume group.D、Create a new filesystem on the new disk and use the mv command to move the data to the new filesystem, and then remove the failing disk from the volume group.

An administrator is ordering a new Power 550. They will mirror rootvg and are concerned about single points of failure.  Which of the following features should be ordered()A、Dual I/O planar, dual disk drives, dual SCSI adaptersB、Dual disk drive enclosures, dual disk drives, extra media bayC、Dual disk drive enclosures, dual disk drives and dual SCSI adaptersD、Dual I/O planar, extra media bay, dual disk drives

You have just added three new hard disks to your Windows 2000 Professional computer. You want to configure all of the disks as two drives. You want the two drives to be as equal in size as possible. You want to configure the non-system drive for the best optimal performance.  What should you do?()A、Extend the system volume onto disk1. Create a single, stripe volume from disk2 and disk3.B、Extend the system volume onto disk2. Create a single, stripe volume from disk1 and disk2C、Extend the system volume onto disk1. Create a single, spanned volume from disk2 and disk3. D、Extend the system volume onto disk1. Create a single, spanned volume from disk1 and disk2.E、Create a single, stripe volume from disk1, disk2, and disk3. F、Create a single spanned volume from disk1, disk2, and disk3.

During the Solution Assurance for a p5 590, Companycom states there is a plan to install OEM Emulex cards in the p5 590. The customer assumes there will be no problem with the plan since IBM resells the Emulex cards. What is the correct response for the customer?()A、The IBM CE will install the cardB、The card will not be supported by IBMC、The AIX device driver should work fineD、The customer is correct, there should be no problem

单选题During the Solution Assurance for a p5 590, Companycom states there is a plan to install OEM Emulex cards in the p5 590. The customer assumes there will be no problem with the plan since IBM resells the Emulex cards. What is the correct response for the customer?()AThe IBM CE will install the cardBThe card will not be supported by IBMCThe AIX device driver should work fineDThe customer is correct, there should be no problem

单选题Companycom is trying to communicate with the service processor of the a new p5 590. However, the customer can not access the service processor. What needs to be done to fix this problem?()AEnable DHCP server on the HMCBConfigure host name and IP address on DNS serverCManually set the IP address of the service processorDConnect a RS-232 cable from the HMC to the service processor

单选题Companycom has a p690 and currently has eight LPARs. They have purchased a p5 590 and wish to migrate their eight LPARs to the new server. The LPARs are running either AIX 5.2 or AIX 5.3 with the current maintenance. What is the LEAST disruptive method for this activity?()ANew install of AIXBMigrate the 7040-61DCUtilize alt_disk_installDUse the enterprise back up strategy

多选题A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer. From which of the following locations can the new storage drives be added?()AFormat commandBHypervisorCComputer ManagementDDisk ManagementEVirtual Center

单选题You have just added three new hard disks to your Windows 2000 Professional computer. You want to configure all of the disks as two drives. You want the two drives to be as equal in size as possible. You want to configure the non-system drive for the best optimal performance. What should you do?()A Extend the system volume onto disk1. Create a single, stripe volume from disk2 and disk3. B Extend the system volume onto disk2. Create a single, stripe volume from disk1 and disk2. C Extend the system volume onto disk1. Create a single, spanned volume from disk2 and disk3. D Extend the system volume onto disk1. Create a single, spanned volume from disk1 and disk2. E Create a single, stripe volume from disk1, disk2, and disk3.F Create a single spanned volume from disk1, disk2, and disk3.

单选题A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()AA CD or DVD with installation mediaBAn internal SCSI adapter in the target LPARCAn Ethernet adapter for access to an FTP serverDAdvanced Power Virtualization feature of the p5 590