单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()AYou can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch BUsing blade servers with the NPIV switch will require more fibre ports on the external fibre switch CStorage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchDThe NPIV switch will count against the number of domains in a fabric
单选题
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()
A
You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch
B
Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch
C
Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch
D
The NPIV switch will count against the number of domains in a fabric
参考解析
解析:
暂无解析
相关考题:
A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack. Which IBM BladeCenter Chassis should be recommended? ()A、BladeCenter EB、BladeCenter HC、BladeCenter TD、BladeCenter HT
A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request?()A、Brocade Enterprise 20-port 8Gb SAN switch module B、Brocade 20-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter share C、Brocade Enterprise 10-port 8Gb SAN switch module D、Brocade 10-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter
A business partner wants to identify risks, develop action plans to manage the risks, and confirm resources required for a successful implementation of a BladeCenter solution to their customer. Which addresses this situation of the following?()A、Conduct a TDAB、Use IBM System xConfiguratioin and Option Guide (COG)C、UsexREFD、Conduct aServerProven Opportunity Request for Evaluation (SPORE)
A customer has a Linux server farm and wants to use IBM Director to manage all of their systems. Which of the following is the preferred installation of IBM Director to fully manage the Linux systems?()A、Install Director Server on a Windows 2000 Server and install the Director agents on the Linux systems.B、Install IBM Director Agent on a Linux server and install the Director Server on the Linux systems.C、Install the Director Server on a Linux server and manage the systems via Linux native SNMP support.D、Install Director Server on a Linux server and install the Director Linux agent on the Linux systems.
An existing IBM customer has some iSeries servers in their environment. The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications. The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms. Which of the following will accomplish this?()A、Share the data over the Ethernet LAN.B、Install the IXA Adapter in the iSeries server.C、Install the IXA Adapter in the xSeries server.D、Attach both servers to an IXS switch.
A customer needs to add three JS22 blade servers. The customer currently has three HS21 Blade servers and one LS41 4-socket Blade Server. Based upon this information, what additional items does the customer need to purchase? ()A、An IBM BladeCenter H chassis for the JS22 Blade serversB、A concurrent KVM daughter cardC、A pair of IBM BladeCenter Power SuppliesD、A second Management Module
A customer wants to expand their current storage environment, but has floor space for only two machine frames or two racks. Their environment consists of IBM SAN Volume Controllers and IBM DS4000 systems. The DS4000 systems are at end of lease. The customer wants the maximum number of disks possible in two frames. Which of the following solutions is best for this customer?()A、add one SVCB、install one DS8700C、install one DS8800D、install one XIV system
You have a junior sales representative working with your largest customer, who needs to build an entry System x Server hardware solution. Which IBM resource should the junior sales representative use? ()A、IBM Sizing GuidesB、IBM System x and BladeCenter Business Partner GuidebookC、IBM Standalone Solutions Configuration Tool (SSCT) D、IBM ServerProven
A customer wants to boot from an iSCSI SAN with their IBM BladeCenter infrastructure running Microsoft Windows Server 2000. What is required for the customer to be able to perform this?()A、Fibre Channel Expansion Card for each Blade ServerB、cKVM Card for each Blade ServerC、iSCSI Expansion Card for each Blade ServerD、4Gb Modular Flash Drive
A customer asks which bays they could install Multi-Switch Interconnect Module (MSIM). Which of the following is the source of this information?()A、CDAT B、IBM Systems Director C、Tivoli Provisioning Manager (TPM) D、BladeCenter Interoperability guide
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()A、You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch B、Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch C、Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchD、The NPIV switch will count against the number of domains in a fabric
A Sales Specialist receives an email from a customer, requesting information on IBM’s best Server Consolidation solution. How should the Sales Specialist proceed? ()A、Send the customer information on VMwareB、Send the customer information on IBM BladeCenter C、Call the customer to ask why they are consolidatingD、Send the customer information on IBM System P
A customer with an IBM Power System running AIX is using an IBM System Storage DS8100 inLocation A, and an IBM System Storage DS5100 in Location B. The distance between Location Aand Location B is 25 kilometers. The customer wants a redundant copy of the data inLocation Bfor disaster recovery. Which of the following solutions will best satisfy this requirement?()A、install FlashCopy on the DS8100 B、install SAN Volume Controllers with FlashCopyC、install SAN Volume Controllers with Metro Mirror D、install Global Mirror on the DS8100 and Enhanced Remote Mirror on the DS5100
A medical customer wants to deploy around 8TB integrated storage on a BladeCenter.Which of the following should be discussed with this customer?()A、SATA internal disksB、iSCSIC、Solid State StorageD、SAS Internal Disk
A manufacturing customer wants a consolidation solution that provides scale-out capability and the highest processor density per rack unit. Which of the following solution meets customer’s requirement?()A、x3650 M3 with Microsoft Virtual ServerB、BladeCenter JS43 with VMwareC、x3850 X5 with VMwareD、BladeCenter HS22V with VMware
A customer wants to improve the utilization of the current capacity of their existing N series Tier 1production storage. What solution would the storage specialist discuss with the customer?()A、 compression with IBM Real-time Compression Appliances B、 deduplication with IBM ProtecTIER C、 virtualization with IBM SVC D、 file virtualization with SONAS
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM). What TRUE statement should be mentioned to the customer regarding the OPM?()A、You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.B、Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.C、The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.D、The blade servers do not work with the Optical Pass-Thru Module.
During the Solution Assurance for a p5 590, Companycom states there is a plan to install OEM Emulex cards in the p5 590. The customer assumes there will be no problem with the plan since IBM resells the Emulex cards. What is the correct response for the customer?()A、The IBM CE will install the cardB、The card will not be supported by IBMC、The AIX device driver should work fineD、The customer is correct, there should be no problem
单选题A customer needs to add three JS22 blade servers. The customer currently has three HS21 Blade servers and one LS41 4-socket Blade Server. Based upon this information, what additional items does the customer need to purchase? ()AAn IBM BladeCenter H chassis for the JS22 Blade serversBA concurrent KVM daughter cardCA pair of IBM BladeCenter Power SuppliesDA second Management Module
单选题During the Solution Assurance for a p5 590, Companycom states there is a plan to install OEM Emulex cards in the p5 590. The customer assumes there will be no problem with the plan since IBM resells the Emulex cards. What is the correct response for the customer?()AThe IBM CE will install the cardBThe card will not be supported by IBMCThe AIX device driver should work fineDThe customer is correct, there should be no problem
单选题A customer wants to realize a server-based computing scenario for trading floor applications with IBM BladeCenter. The customer expects the solution to offer high security and manageability, while delivering hardware-based graphics compression and full USB capability. Is this possible?()A AB BC CD D
单选题A manufacturing customer has an IBM BladeCenter H chassis with four, HX5 with MAX5 4-socket blades installed. Each blade has the optional Fibre Channel Expansion card. The customer wants redundancy and is going to install the following configuration: (1)two Brocade 20-Port SAN Switch Modules (2)two Nortel Networks 1/10 GB Uplink ESM (3)a redundant AMM What is the minimum number of power supplies needed for this configuration to have full redundancy?()A4B3C2D8
单选题A customer has a Linux server farm and wants to use IBM Director to manage all of their systems. Which of the following is the preferred installation of IBM Director to fully manage the Linux systems?()AInstall Director Server on a Windows 2000 Server and install the Director agents on the Linux systems.BInstall IBM Director Agent on a Linux server and install the Director Server on the Linux systems.CInstall the Director Server on a Linux server and manage the systems via Linux native SNMP support.DInstall Director Server on a Linux server and install the Director Linux agent on the Linux systems.
单选题A customer wants to boot from SAN with their IBM BladeCenter infrastructure. What is required for the customer to be able to perform this? ()A4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server BCisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module CFibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module DCisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server
单选题A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. Theustomer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy? ()A12 B10 C8 D6
单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()AYoucan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet SwitchBUsing blade servers with the NPIV switch will require morefibre ports on the external fibre switchCStorage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.DThe NPIV switch will count against the number of domains in a fabric
单选题A new customer wants to install a Power 750 in a warehouse location that has no local staff to support it. They are concerned about hardware support and would like to have the system notify IBM service if there is an issue.Which actions will address the customer concern?()AEnable automatic problem reporting from smitBUse IVM to enable console mirroring to IBM Remote Support.CUse the HMC to enable reporting through Electronic Service Agent.DEnable Automatic Problem Reporting in ASMI using he embedded modem on the FSP.
单选题A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack. Which IBM BladeCenter Chassis should be recommended? ()ABladeCenter EBBladeCenter HCBladeCenter TDBladeCenter HT