单选题he Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vSphere environments running the Cisco NX-OS Software operating system. Together with the VMware ESX hypervisor, the Nexus 1000V supports Cisco VN-Link server virtualization technology, which provides mobile virtual machine security and network policy for VMware View components, including the DHCP snooping feature. DHCP snooping is disabled on the Nexus 1000V by default. When the DHCP snooping feature is enabled on the Nexus 1000V, what are the default trust settings for the vEthernet and uplink ports?()A All vEthernet ports are trusted, and all Ethernet ports such as uplinks and port channels are trusted.B All vEthernet ports are not trusted, and all Ethernet ports such as uplinks and port channels are not trusted.C All vEthernet ports are trusted and all Ethernet ports such as uplinks and port channels are not trusted.D All vEthernet ports are not trusted and all Ethernet ports such as uplinks and port channels are trusted.
单选题
he Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vSphere environments running the Cisco NX-OS Software operating system. Together with the VMware ESX hypervisor, the Nexus 1000V supports Cisco VN-Link server virtualization technology, which provides mobile virtual machine security and network policy for VMware View components, including the DHCP snooping feature. DHCP snooping is disabled on the Nexus 1000V by default. When the DHCP snooping feature is enabled on the Nexus 1000V, what are the default trust settings for the vEthernet and uplink ports?()
A
All vEthernet ports are trusted, and all Ethernet ports such as uplinks and port channels are trusted.
B
All vEthernet ports are not trusted, and all Ethernet ports such as uplinks and port channels are not trusted.
C
All vEthernet ports are trusted and all Ethernet ports such as uplinks and port channels are not trusted.
D
All vEthernet ports are not trusted and all Ethernet ports such as uplinks and port channels are trusted.
参考解析
解析:
暂无解析
相关考题:
To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?() A. to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkB. to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkC. to two core switches from redundant distribution switches connected with a Layer 2 linkD. to two core switches from redundant distribution switches connected with a Layer 3 linkE. to two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
Which statement about the Adapter FEX feature on the Cisco Nexus 5000 Series Switches is true?()A、 Adapter FEX is a software feature that can be configured on any CNA as long as the Nexus 5000 is running a version of code that supports Adapter FEXB、 Adapter FEX can be thought of as a way to divide a single physical link into multiple virtual links or channels.C、 Packets on each channel are tagged with an 801.Q header that has a specific source VIFD、 When using a dual-homed NIC on the server, active/standby is not supported. Only active/active is supported.
Which statement best describes ACL configuration using configuration session mode on Cisco Nexus switches?()A、 The verify command will validate commands entered for syntax errors.B、 The save command will save the commands entered to the startup configuration.C、 The network administrator can perform a dry-run ACL configuration by verifying the configuration against the hardware and software resources available before applying it.D、 Configuration sessions can be saved and resumed at any time, even after upgrading NX-OS Software on the switch with ISSU.E、 Configuration sessions are global for all VDCs on the Nexus 7000.
Which two management-software applications can you use to manage the Cisco Catalyst Express 500 Series Switches?()A、Cisco Network AssistantB、Cisco Security Device ManagerC、Cisco Device ManagerD、Cisco Adaptive Security Device Manager
Which type of software would the Cisco Catalyst 2950 Series switches use to deliver intelligent services to networks that require additional security, advanced QoS, and high availability?()A、 Enhanced ImageB、 StandardImagC、 Cisco IOS softwareD、 Enhanced Multilayer Software Image
To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?()A、 to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkB、 to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkC、 to two core switches from redundant distribution switches connected with Layer 2 linkD、 to two core switches from redundant distribution switches connected with Layer 3 linkE、 to two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
Which Cisco product performs virtualized Ethernet switching within a VMware ESX host?()A、Nexus l000B、Nexus 2000C、Nexus 5000D、Nexus 7000
Which two statements best explain why the Cisco Catalyst 6500 Series of switches best fits in thecore area? ()A、 Cisco Catalyst 6500 Series offer a broad set of access capabilities.B、 Cisco Catalyst 6500 Series eliminate network security threats.C、 Cisco Catalyst 6500 Series handle high amounts of traffic flow.D、 Cisco Catalyst 6500 Series aggregate data from the distribution-area switches.
A switch that is to be added to the production network has been preconfigured (trunks, VLANs, VTP, and STP) and was tested in your lab. After installing the switch into the network, the entire network went down. What might explain what happened? ()A、The new switch happened to be running Cisco Catalyst operating system, while the other network switches were running Cisco IOS Software.B、The configuration revision of the new switch was higher than the configuration revision of the production VTP domain.C、The link costs on the new switch are set to a high value, causing all ports on the new switch to go into a forwarding mode and none into blocking mode, thereby causing a spanning-tree loop.D、The ports connecting to the two switches have been configured incorrectly. One side has the command switchport mode access and the other switchport mode trunk.
Which three statements best describe multicast operation on Cisco Nexus switches in a data center?()A、 Cisco NX-OS Software does not support PIM dense mode.B、 The command ip multicast-routing must be enabled in Cisco NX-OS Software before any multicast configuration is possible on the switch.C、 PIM CLI configuration and verification commands are not available until you enable the PIM feature with the feature pim command.D、 Cisco NX-OS Software supports multicast routing per Layer 3 VRF instance.E、 The default PIM operational mode on the Cisco Nexus 7000 switch is SSM.
Cisco Catalyst 4500 Series switches are attractive to medium-size campuses with growth opportunities due to the switches enhanced security and which two other features? ()A、 enhanced multilayer software imageB、 connectivity to multiple types of WAN connectionsC、 Cisco Unified Communications ManagerD、 QoS for converged networksE、 modular, customizable components
The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect multiple units?()A、 Cisco Express Catalyst 500 Series switchesB、 Cisco Catalyst 2900 Series switchesC、 Cisco Catalyst 3560 switchesD、 Cisco Catalyst 3700 Series switchesE、 Cisco Catalyst 4500 Series switchesF、 Cisco Catalyst 6500 Series switches
If an enterprise customer required A switch for their branch office access layer, which family of switches would the customer likely choose from?()A、Cisco SFS 3000/7000B、Cisco Catalyst 2000 and 3000C、Cisco Catalyst 4000 and 6000D、Cisco Nexus
Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()A、UCS MangerB、virtual supervisor moduleC、virtual ethernet moduleD、distributed virtual switch
In Cisco Nexus 1000V deployments which two statements are true?()A、Vmware provides the VNIC and driversB、Vmware provides the VNIC and Cisco provides the driversC、Cisco provides the switching and management of switchingD、Cisco provides the switching and Vmware provides the management of switching
Which statement about Cisco Unified Fabric switches is correct? () A、 The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B、 The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C、 The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D、 The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E、 The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.
he Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vSphere environments running the Cisco NX-OS Software operating system. Together with the VMware ESX hypervisor, the Nexus 1000V supports Cisco VN-Link server virtualization technology, which provides mobile virtual machine security and network policy for VMware View components, including the DHCP snooping feature. DHCP snooping is disabled on the Nexus 1000V by default. When the DHCP snooping feature is enabled on the Nexus 1000V, what are the default trust settings for the vEthernet and uplink ports?() A、 All vEthernet ports are trusted, and all Ethernet ports such as uplinks and port channels are trusted.B、 All vEthernet ports are not trusted, and all Ethernet ports such as uplinks and port channels are not trusted.C、 All vEthernet ports are trusted and all Ethernet ports such as uplinks and port channels are not trusted.D、 All vEthernet ports are not trusted and all Ethernet ports such as uplinks and port channels are trusted.
The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect?()A、 Cisco Express Catalyst 500 Series switchesB、 Cisco Catalyst 2900 Series switchesC、 Cisco Catalyst 3560 switchesD、 Cisco Catalyst 3700 Series switchesE、 Cisco Catalyst 4500 Series switchesF、 Cisco Catalyst 6500 Series switches
单选题The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect multiple units?()A Cisco Express Catalyst 500 Series switchesB Cisco Catalyst 2900 Series switchesC Cisco Catalyst 3560 switchesD Cisco Catalyst 3700 Series switchesE Cisco Catalyst 4500 Series switchesF Cisco Catalyst 6500 Series switches
单选题Which statement about Cisco Unified Fabric switches is correct? ()A The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.
单选题Which type of software would the Cisco Catalyst 2950 Series switches use to deliver intelligent services to networks that require additional security, advanced QoS, and high availability?()A Enhanced ImageB StandardImagC Cisco IOS softwareD Enhanced Multilayer Software Image
单选题A switch that is to be added to the production network has been preconfigured (trunks, VLANs, VTP, and STP) and was tested in your lab. After installing the switch into the network, the entire network went down. What might explain what happened? ()AThe new switch happened to be running Cisco Catalyst operating system, while the other network switches were running Cisco IOS Software.BThe configuration revision of the new switch was higher than the configuration revision of the production VTP domain.CThe link costs on the new switch are set to a high value, causing all ports on the new switch to go into a forwarding mode and none into blocking mode, thereby causing a spanning-tree loop.DThe ports connecting to the two switches have been configured incorrectly. One side has the command switchport mode access and the other switchport mode trunk.
单选题To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?()Ato a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkBto a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkCto two core switches from redundant distribution switches connected with a Layer 2 linkDto two core switches from redundant distribution switches connected with a Layer 3 linkEto two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
多选题Which three statements best describe multicast operation on Cisco Nexus switches in a data center?()ACisco NX-OS Software does not support PIM dense mode.BThe command ip multicast-routing must be enabled in Cisco NX-OS Software before any multicast configuration is possible on the switch.CPIM CLI configuration and verification commands are not available until you enable the PIM feature with the feature pim command.DCisco NX-OS Software supports multicast routing per Layer 3 VRF instance.EThe default PIM operational mode on the Cisco Nexus 7000 switch is SSM.
单选题Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()AUCS MangerBvirtual supervisor moduleCvirtual ethernet moduleDdistributed virtual switch
单选题Which statement best describes ACL configuration using configuration session mode on Cisco Nexus switches?()A The verify command will validate commands entered for syntax errors.B The save command will save the commands entered to the startup configuration.C The network administrator can perform a dry-run ACL configuration by verifying the configuration against the hardware and software resources available before applying it.D Configuration sessions can be saved and resumed at any time, even after upgrading NX-OS Software on the switch with ISSU.E Configuration sessions are global for all VDCs on the Nexus 7000.
单选题Which statement about the Adapter FEX feature on the Cisco Nexus 5000 Series Switches is true?()A Adapter FEX is a software feature that can be configured on any CNA as long as the Nexus 5000 is running a version of code that supports Adapter FEXB Adapter FEX can be thought of as a way to divide a single physical link into multiple virtual links or channels.C Packets on each channel are tagged with an 801.Q header that has a specific source VIFD When using a dual-homed NIC on the server, active/standby is not supported. Only active/active is supported.