单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorAⅠ+ⅡBⅠ+ⅢCⅡ+ⅢDⅠ+Ⅱ+Ⅲ

单选题
When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incinerator
A

Ⅰ+Ⅱ

B

Ⅰ+Ⅲ

C

Ⅱ+Ⅲ

D

Ⅰ+Ⅱ+Ⅲ


参考解析

解析: 暂无解析

相关考题:

When an incinerator goes out suddenly, theosupply should be shut off quickly A.fuelB.sludgeC.airD.fuel and sludge

The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

The oil sludge is burnt in the ______onboard.I’ll show you the ashes.A.boilerB.main engineC.auxiliary engineD.incinerator

The oil sludge is burnt in the ______onboarA.I’ll show you the ashes.B.boilerC.main engineD.auxiliary engineE.incinerator

A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A、check for a faulty IDE cableB、be sure that the DVD+R is formatted before using itC、check for incompatible mediaD、re-install the DVD burning software

When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?()  A、 To indicate the location of the auxiliary-instance online redo logs.B、 To indicate the location of the target database datafiles.C、 To indicate the location of the auxiliary-instance control file and online redo logs.D、 To indicate the location of the auxiliary-instance database datafiles.E、 This is not a valid parameter when duplicating a database.

单选题A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()Acheck for a faulty IDE cableBbe sure that the DVD+R is formatted before using itCcheck for incompatible mediaDre-install the DVD burning software

单选题The velocity of a rotary tidal current will be decreased when the Moon is().Aat apogeeBnewCfullDAll of the above

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题On the all-purpose nozzle,the position of the valve when the handle is all the way forward is().AshutBfogCsolid streamDspray

单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorAⅠ+ⅡBⅠ+ⅢCⅡ+ⅢDⅠ+Ⅱ+Ⅲ

单选题The all-purpose nozzle will produce a fog spray when you().Apull the nozzle handle all the way back toward the operatorBpull the nozzle handle back to a position where the handle is perpendicular to the plane of the nozzleCpush the nozzle handle forward as far as it will goDinsert a fog applicator between the fire hose and nozzle

单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished

单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().Afuel pump failureBfan motor failureCincreased feedwater consumptionDdecreased boiler efficiency

单选题During waste clothes being charged into an incinerator, the auxiliary burner().Ashould be stopped manuallyBkeeps the combustion as usualCwould be cut off by an interlockDwould replace the waste oil burner and keep going on

单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()Awater in the fuel oilBbroken high tension leadsCincorrect electrode settingDfull fuel pressure at the nozzle

单选题When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbishAⅠ+Ⅱ+Ⅲ+ⅤBⅠ+Ⅱ+Ⅲ+ⅣCⅠ+Ⅳ+Ⅴ+ⅥDⅠ+Ⅱ+Ⅲ+Ⅵ

单选题When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbishAⅠ+Ⅱ+Ⅲ+ⅤBⅠ+Ⅱ+Ⅲ+ⅣCⅠ+Ⅳ+Ⅴ+ⅥDⅠ+Ⅱ+Ⅲ+Ⅵ

单选题High exhaust temperature and black smoke exhausting from an auxiliary diesel engine can be caused by ().Aengine overloadBlow combustion temperatureCplugged fuel nozzle holesDexcessive compression pressure

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdrum level to stabilize

单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()Adefective solenoid valveBdirty fuel nozzleCgrounded high tension leadDfaulty ignition cable connector

单选题When using a high-velocity fog stream in a passageway,the possibility of a blow back must be guarded against. Blow back is most likely to occur when().Apressure builds up in the nozzle which causes a surge of waterBthe only opening in a passageway is the one from which the nozzle is being advancedCpressure in the fire hose drops below 100 psiDa bulkhead collapses due to heat and pressure

单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()Aa burned out solenoid in the oil supply valveBhigh temperature excess airCincorrectly setting the hot-well dump valveDan incorrectly positioned burner snubber realy

单选题Heavy soot accumulations in an auxiliary boiler could be caused by()Awater in the fuel oilBexcessive cyclingChigh fuel oil pressureDimproper burner maintenance

单选题Concerning the incinerator’s operation, which of the following is not correct?()AScavenging time should be more 30 seconds before ignitingBThe temperature of sludge tank is 80~100℃CFirst igniting the incinerator with diesel oil, when the temperature of health is about 600℃, the sludge oil drawn inDThe ash can be dumped into sea when the distance is more than 3 miles from land

单选题When the incinerator is stopped, which of the following is wrong?()AAfter stopping supplying sludge oil, the value and pipe should be flushed by flushed by diesel oil and the incinerator continue burning for 10 minutesBClose auxiliary burner firstly and then close main burnerCAfter stopping fuel, restoring the position of main fuel supply valveDStop blower as soon as stopping supplying fuel oil

单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()Aincorrect electrode settingBincorrect nozzle positionCclogged fuel nozzleDbroken high tension lead

单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdram level to stabilize