单选题()can not cause oil flow from water outlet of self-cleaning separator.AOil temperature too highBDiameter of gravity disc too largeCOil temperature too lowDHigh level tank out of water

单选题
()can not cause oil flow from water outlet of self-cleaning separator.
A

Oil temperature too high

B

Diameter of gravity disc too large

C

Oil temperature too low

D

High level tank out of water


参考解析

解析: 暂无解析

相关考题:

One of the reasons that causes oil flowed from sludge outlet of a self-cleaning purifier isA.seal water supply be cut offB.make-up water supply be cut offC.oil outlet valve closed or not open sufficientlyD.the flow rate of oil is too much

第二组The only attention that heat exchanger should require is to ensure that the heat transfer surfaces remain substantially clean and the flow passages generally clear of obstruction. Indication that undue fouling is occurring is given by a progressive increase in the temperature difference between the two fluids, over a period of time, usually accompanied by a noticeable rise in pressure loss at a given flow.Fouling on the sea-water side is the most usual cause of deterioration in performance. The method of cleaning the sea water-side surfaces depends on the type of heat exchanger. With shell-and-tube heat exchangers, the removal of the header covers or, m the case of the smaller heat exchangers, the headers themselves, will provide access to the tubes. Obstructions, dirt, scale etc., can then be removed, using the tools provided by the heat exchanger manufacturer. Flushing through with fresh water is recommended before a heat exchanger is returned to service. In some applications, such as piston oil cooling, progressive fouling may take place on the outside of the tubes. Most manufactures recommend a chemical flushing pr6cess to remove this in situ~ without dismantling the heat exchanger.Plate heat exchangers may be cleaned by unclamping the stack of plates and mechanically cleaning the surface of each plate as recommended by the manufacturers. The plate seals may require replacement from time to time and here the manufacturers instructions should be closely followedBy which of the following indication, can we conclude that the lube oil-sea water heat exchanger is unduly fouled?A.the heat exchanger lube oil inlet temperature loweringB.the heat exchanger sea-water outlet pressure riseC.the heat exchanger temperature difference between lube oil and sea water increasingD.the heat exchanger pressure difference between sea water inlet and outlet decreasing

_______can cause oil flow from water outlet of the oil purifier.A.Oil inlet valve opening too quicklyB.Oil temperature little higher than normalC.Diameter of gravity disc too smallD.Viscosity of oil little lower than normal

Before loading bulk grain, bilge wells must be covered to ______.A.add strength to the bilge well strainerB.permit rapid flow of water to the bilge wellsC.prevent cargo sifting into the bilge wellsD.prevent oil, water, or other liquid from reaching the cargo

单选题()can be used to prevent hydraulic system overloaded or keep the pressure of oil outlet from pump constant.AOverflow valveBReducing valveCBalancing valveDReducing valve or balancing valve

单选题If the cooling water temperature and the lube oil temperature in a diesel engine are too high, the cause can be ()Aa dirty lube oil strainerBinternal water leaksCan oil suction line restrictionDexcessive wears of the cooling water pump

单选题A dirty fuel oil filter element can be detected by ()AVisual inspection of the elementBthe pressure drop cross the filterChigh fuel oil tank temperatureDincrease flow rate from the filter

单选题Black smoke coming from a boiler can be caused by ().Alow water levelBhigh water levelCexcessively high fuel pressureDlow oil temperature

单选题The three conditions which cause engine shutdown are overspeed,low lube oil pressure,and().AHigh lube oil pressureBHigh jacket water pressureCHigh jacket water temperatureDLow jacket water pressure

单选题Before loading bulk grain,bilge wells must be covered to().Aadd strength to the bilge well strainerBpermit rapid flow of water to the bilge wellsCprevent cargo sifting into the bilge wellsDprevent oil,water,or other liquid from reaching the cargo

单选题White smoke exhausting from a diesel engine can result from ()Ahigh exhaust temperatureBhigh lube oil temperatureClow turbo-charger speedDlow cooling water temperature

单选题The () of the gravity disc is too big It causes oil to flow through the water outletWe changed the disc and no oil is found in the water outlet.AgravityBdiameterCcircumferenceDcylinder

单选题()can cause oil flow from water outlet of a separator.AOil inlet valve opening too quicklyBOil temperature too highCDiameter of gravity disc too smallDViscosity of oil too low

单选题The diameter of the gravity disc is too big It causes oil to flow through the water outlet We changed the disc and no () is found in the water outlet.AwaterBoilCscaleDridge

单选题A diesel engine fails to start due to excessive water in the fuelBefore the engine can be started, the water should be removed from the()Afuel linesBlube oil filterCcrank case pumpDrocker arm reservoir

单选题Which of the following conditions indicates the dilution of diesel engine lube oil by fuel oil?()AWater discharging from the water outlet of the lube oil purifierBFuel oil discharging from the water outlet of the lube oil purifierCLube oil discharging from the water outlet of the lube oil purifierDA change in the lube oil viscosity

单选题When finish work on the oil separator, you should()firstly.Acut off the powerBcut off the oil inletCopen guide water valveDclose oil outlet value

单选题The outlet from an expansion tank of a closed freshwater cooling system should be piped to the ().Acylinder head water outlet headerBcylinder jacket inlet mainCheat exchanger inlet connectionDjacket water pump suction line

单选题In a four-stroke/cycle diesel engine, badly worn intake valve guides can cause excessive().Aexhaust pressureBexhaust temperaturesCcooling water temperaturesDlube oil consumption

单选题()can cause oil flow from sludge outlet of self cleaning separator.AToo much sludge accumulated in separator bowlBDiameter of gravity disc too largeCHigh level tank lack of waterDOil input too rapidly

单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat

单选题Which of the following statements is true concerning an oil cooler?()AThe oil temperature is less than the cooling water temperatureBThe oil pressure is less than the cooling water pressureCThe oil pressure is greater than the cooling water pressureDThe oil flow control valve is always installed in the oil input line

单选题For a L√Opurifier, if the back pressure of the oil outlet is too high, the interface between oil and water in the bowl will ().Abe interruptedBmove downwardsCmove outwardsDretain original position

单选题One of the reasons that cause oil flowed from sludge outlet of a self-cleaning separator is()Aseal water supply be cut offBmake up water supply be cut offCoil outlet valve closed or not open sufficientlyDthe flow rate of oily water is too much

单选题One of the reasons that causes oil flowed from sludge outlet of a self-cleaning purifier is ()Aseal water supply be cut offBmake-up water supply be cut offCoil outlet valve closed or not open sufficientlyDthe flow rate of oil is too much

单选题Just after stopping the engine while the oil is still circulating.Check that uniform oil jets appear from all the oil outlet grooves in the crosshead bearing lower shell and the guide shoes.The oil flow from () must be compared from unit; there should be a similarity in the flow patterns.Athe piston cooling oil return pipesBthe main and crankpin bearingsCthrust and intermediate bearingsDstern tube and thrust bearings

单选题Which of the listed failures, occurring in an automated diesel generator system, should cause an audible alarm at the engine room control station?()ALow cooling water outlet temperatureBHigh lube oil pressureCLow lube oil temperatureDLow starting air pressure