单选题A customer intends to implement a Fibre Channel SAN at the production site. Replication will take place over a 10 kilometer Ethernet connection to a second site; however, only IP storage connectivity currently exists at the second site. Which is the most appropriate method of replication in this situation?()AFC routingBFCoE connectionCFC-IP tunnelingDmulti-protocol router

单选题
A customer intends to implement a Fibre Channel SAN at the production site. Replication will take place over a 10 kilometer Ethernet connection to a second site; however, only IP storage connectivity currently exists at the second site. Which is the most appropriate method of replication in this situation?()
A

FC routing

B

FCoE connection

C

FC-IP tunneling

D

multi-protocol router


参考解析

解析: 暂无解析

相关考题:

Which of the following provides Fibre Channel over IP and FCIP Tunneling Service for distance extension, which can enable cost-effective and manageable metro and global business continuity solutions?()A. IBM System Storage SAN80B-4B. IBM System Storage SAN Volume Controller (SVC)C. IBM System Storage SAN04B-R Multi-Protocol RouterD. IBM System Storage TS7650GProtecTIER Deduplication Gateway

A customer intends to implement a Fibre Channel SAN at the production site. Replication will take place over a 10 kilometer Ethernet connection to a second site; however, only IP storage connectivity currently exists at the second site.Which is the most appropriate method of replication in this situation?()A. FC routingB. FCoE connectionC. FC-IP tunnelingD. multi-protocol router

In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A、One fibre channel switchB、Two fibre channel switchesC、Two Ethernet cardsD、Nothing

Which of the following provides Fibre Channel over IP and FCIP Tunneling Service for distance extension, which can enable cost-effective and manageable metro and global business continuity solutions?()A、IBM System Storage SAN80B-4B、IBM System Storage SAN Volume Controller (SVC)C、IBM System Storage SAN04B-R Multi-Protocol RouterD、IBM System Storage TS7650GProtecTIER Deduplication Gateway

A company wants a solution to consolidate their storage using the DS4000 series and implement a disaster recovery solution across two data centers linked by fibre to duplicate the production environment.The customer requires a solution with the least amount of system administration.  Which configuration would provide the best solution?()A、Implement one DS4400 at each location connected to the fibre link and use Remote Volume Mirror (RVM).B、Implement a DS4400 at each location using FlashCopy option and use host based replication to synchronize the sites.C、Implement a switched fabric using redundant SAN switches with a DS4300 using RVM option at each location.D、Implement a switched fabric using SAN switches connected via ISL with a DS4300 using RVM option at each location.

A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()A、Ask the customer to confirm which option is best for their environment.B、Order the fibre channel option and purchase a converter later if necessary.C、Order both SCSI and fibre channel adapters to cover both potential options.D、Inform the customer that fibre channel was selected for performance reasons.

A customer intends to implement a Fibre Channel SAN at the production site. Replication will take place over a 10 kilometer Ethernet connection to a second site; however, only IP storage connectivity currently exists at the second site. Which is the most appropriate method of replication in this situation?()A、FC routingB、FCoE connectionC、FC-IP tunnelingD、multi-protocol router

A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

A customer’s current backup environment uses IBM Tivoli Storage Manager (TSM) over thecorporate LAN. A 500 GB Oracle database application was recently added to the SAN. Backupwindows are no longer being met. Which action should the storage specialist recommend?()A、virtualize the storage with SVCB、implement TSM for space managementC、implement TSM for Storage Area NetworksD、add an additional Ethernet card to the TSM server

The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()A、IBM DS8700 B、IBM N6040 C、IBM Storwize V7000 D、IBM XIV Storage System

A customer is planning a PowerHA cluster split across two sites. The sites are located 10km apart. There is aDS8000 storage array at each site with SAN connectivity between the two arrays. There are only enough IPinterfaces for one IP network in this cluster. How can they ensure that disk data is automatically mirrored and synchronized between sites?()A、Purchase PowerHA/XD licenseB、Purchase PowerHA with GLVM licenseC、Implement PowerHA with split-site LVMD、Implement PowerHA with cross-site LVM

A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()A、Fiber Channel Switch ModuleB、Gb Ethernet expansion cardC、Myrinet Cluster expansion cardD、Ethernet Switch Module

A customer has two locations located 7 kilometers apart. The production site has a Cisco 9509chassis with 48 Fibre Channel ports activated, and the disaster recovery site has a Cisco 9509chassis with 48 Ethernet ports activated. Which of the following products will be used to get thedata from one location to the other?()A、IBM SAN40-B4B、Cisco MDS 9222iC、Cisco MDS 9148D、IBM SAN32B-E4 with encryption

A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2 CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

单选题A customer intends to implement a Fibre Channel SAN at the production site. Replication will take place over a 10 kilometer Ethernet connection to a second site; however, only IP storage connectivity currently exists at the second site. Which is the most appropriate method of replication in this situation?()AFC routingBFCoE connectionCFC-IP tunnelingDmulti-protocol router

单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A Only to Cisco Fibre Channel switchesB Only to Cisco Fibre Channel switches in NPIV modeC To any Fibre Channel switchD Directly to storage arraysE Only to Nexus Switches

单选题A customer has defined their server needs as a four-LPAR 16-way p570 with 64GB of memory, four 10/100/1000 TX LAN adapters, and six fibre channel adapters to external storage in an IBM ESS (Shark).  They like the idea of being able to do SAN maintenance while not incurring downtime.  If all LPARs are production related and similar, which question is most appropriate for the pSeries technical specialist to ask?()AWould 10/100 Ethernets work as well?BShould there be eight fibre channel adapters?CShould there be an async adapter for heartbeat?DWill all LPARs need access to a common fibre channel tape drive?

单选题A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()AOne fibre channel switchBTwo fibre channel switchesCTwo Ethernet cardsDNothing

单选题A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()AConfigure 2 CFFh combination fibre channel / gigabit Ethernet adaptersBConfigure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterCConfigure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterDConfigure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

单选题A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()AAsk the customer to confirm which option is best for their environment.BOrder the fibre channel option and purchase a converter later if necessary.COrder both SCSI and fibre channel adapters to cover both potential options.DInform the customer that fibre channel was selected for performance reasons.

单选题Which of the following provides Fibre Channel over IP and FCIP Tunneling Service for distance extension, which can enable cost-effective and manageable metro and global business continuity solutions?()AIBM System Storage SAN80B-4BIBM System Storage SAN Volume Controller (SVC)CIBM System Storage SAN04B-R Multi-Protocol RouterDIBM System Storage TS7650GProtecTIER Deduplication Gateway

单选题A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()AFiber Channel Switch ModuleBGb Ethernet expansion cardCMyrinet Cluster expansion cardDEthernet Switch Module

单选题The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()AIBM DS8700 BIBM N6040 CIBM Storwize V7000 DIBM XIV Storage System

单选题A customer has two locations located 7 kilometers apart. The production site has a Cisco 9509chassis with 48 Fibre Channel ports activated, and the disaster recovery site has a Cisco 9509chassis with 48 Ethernet ports activated. Which of the following products will be used to get thedata from one location to the other?()AIBM SAN40-B4BCisco MDS 9222iCCisco MDS 9148DIBM SAN32B-E4 with encryption

单选题A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()AConfigure 2CFFh combination fibre channel / gigabit Ethernet adaptersBConfigure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterCConfigure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterDConfigure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

单选题Which of the following computer recovery sites is only partially equipped with processing equipment?下列哪项计算机恢复站点只有部分数据处理设备?()Ahot site. 热站Bcold site. 冷站Cwarm site. 温站Drolling hot site. 移动热站