单选题In a centrifugal Freon refrigeration system, the overall capacity of the system is increased by()Aopening more bypass linesBopening additional expansion valvesCadding refrigerantDspeeding up the machine

单选题
In a centrifugal Freon refrigeration system, the overall capacity of the system is increased by()
A

opening more bypass lines

B

opening additional expansion valves

C

adding refrigerant

D

speeding up the machine


参考解析

解析: 暂无解析

相关考题:

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve

Which of the following logs contains information on overall performance and events not related to user authentication?()A、SecurityB、AuditC、ApplicationD、System

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题The refrigeration system low pressure cutout switch is actuated by ().Aan electric system managerBa sensing bulb at the tail coil of the evaporatorCpressure changes in the suction lineDfailure of the king solenoid valve

单选题The latent heat of evaporation is dissipated in the () in a compression refrigeration system.AevaporatorBcondenserCexpansion valveDcompressor

单选题In a centrifugal Freon refrigeration system, the overall capacity of the system is increased by()Aopening more bypass linesBopening additional expansion valvesCadding refrigerantDspeeding up the machine

单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator

单选题If no gaskets are used in the piping joints of a Freon system, the joints must be()Afinished jointsBwelded jointsCground jointsDsoldered joints

单选题When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().AdehydratedBpurgedCpluggedDevacuated

单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.AfilterBfilter drierCheat exchangerDair cooler

单选题Where is the cooling water from the compensating tank in the cooling water system of main engine lead to?()Adischarge side of the centrifugal pumpBsuction side of the centrifugal pumpCthe lowest point of the cooling water systemDinlet of the main engine

单选题Air or noncondensable gas is removed from a refrigeration system by a ()Aseparating chamberBsystem of bafflesCpurge valveDvacuum reducing valve

单选题Zinc rods are installed in the refrigeration system ().Aliquid strainerBliquid receiverCsaltwater condenserDevaporator

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题In which of the listed refrigeration system components does superheating of the refrigerant take place?()AExpansion valveBEvaporatorCDrierDReceiver

单选题A liquid sight flow indicator in a refrigeration system is examined and gas bubbles are noted in motion with the fluid flowThis means ().Athe system is fully chargedBthere is air leaking in from the condenserCice crystals are forming in the refrigerantDthe system contains less than a full charge of refrigerant

单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system

单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator

单选题The expansion valve on a Freon system controls the ().Asuperheat of the gas leaving the compressorBback pressure in the evaporatorCtemperature of the iceboxDsuperheat of the gas leaving the evaporator

单选题Saltwater is typically provided to a refrigeration system to ().Acool the expansion valveBprevent refrigerant superheatingCcondense the refrigerant gasDprevent motor overheating

单选题Moisture in a refrigeration system can cause ().Afreezing the expansion valve closedBcorrosion of system pipingCimproper temperature regulationDall of the above

单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().AliquidBdry saturated gasCwet saturated gasDsuperheated vapor

单选题Which of the listed statements is correct concerning refrigeration systems?()ADehydrators must be used continuously in a refrigeration systemBA 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursCA thermostatic expansion valve is used to control refrigerated space temperatureDThe liquid receiver functions to collect and remove non- condensable gases

单选题A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()Apurge lube oil from the liquid refrigerantBrecover water purged from the systemCseparate foul gases from the receiverDpurge non-condensable gases without losing refrigerant

单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor