单选题To determine the number of portable fire extinguishers required on an inspected vessel,you should check the().Ahot work permitBCertificate of InspectionCSafety of Life at Sea CertificateDstation bill

单选题
To determine the number of portable fire extinguishers required on an inspected vessel,you should check the().
A

hot work permit

B

Certificate of Inspection

C

Safety of Life at Sea Certificate

D

station bill


参考解析

解析: 暂无解析

相关考题:

When will the fire department come to conduct a fire prevention inspection in our company?A. Next month. I’ve checked hydrants and fire-extinguishers on each floorB.Next day. The manager will check hydrants and other equipment in the building.C.Next week. But hydrants and fire extinguishers on each floor has already been checkedD.The day before yesterday. I had already checked hydrants and fire extinguishers on each floor.

Portable carbon dioxide fire extinguishers should be sent ashore to be rechargedA.when the remaining charge volume is less than 90 percent of the required volumeB.at each inspection for certificationC.at each annual inspectionD.when the weight loss exceeds 10% of weight of charge

The required number and type of hand portable fire extinguishers for staterooms on cargo vessels is ______.A.one A-IB.one B-IC.one C-ID.none required

To determine the number of portable fire extinguishers required on an inspected vessel,you should check the ______.A.hot work permitB.Certificate of InspectionC.Safety of Life at Sea CertificateD.station bill

All portable fire extinguishers must be capable of being ______.A.carried by hand to a fireB.carried or rolled to a fireC.recharged in the fieldD.used on class “B” fire

Each hand portable fire extinguisher on M/V Utopia must be marked with______.A.the date that it was installed on the unitB.the names of the individuals qualified to use itC.the name of the unit on which it is locatedD.an identification number different from other extinguishers on the unit

Foam-type portable fire extinguishers are most useful in combating fires involving ______.A.solid materials such as wood or bales of fiberB.inflammable liquidsC.electrical equipmentD.metallic solids

Fire in the cabins. Close all fire doors and use the ()powder extinguisher.A、dryB、wetC、foamD、portable

Carry ()(手提灭火器)to the fire place.A、extinguishersB、portable extinguishersC、dry foam extinguishersD、CO2 extinguishers

CO2 and Halon extinguishers are used for electrical fire, as well as ()fire.A、commonB、oilC、electricalD、chemical

单选题Foam-type portable fire extinguishers are more usefull in combating fires involving().Asolid materials such as wood or bales of fiberBinflammable liquidsCelectrical equipmentDmetallic solids

单选题Portable foam type fire extinguishers are most effective on().Amattress firesBoil firesCwood firesDAll of the above

单选题If a CO2 fire extinguisher is not readily available, which of the listed fire extinguishers would be best suited to combat a small electrical fire in a switchboard?()ADry chemicalBHalonCLow velocity fogDSteam

单选题Fire extinguishers of sizes III,IV,and V are designated as().AportableBsemi-portableCfixedDdisposable

单选题Portable carbon dioxide fire extinguishers should be sent ashore to be recharged ().Awhen the remaining charge volume is less than 90 percent of the required VOLUMEBat each inspection for certificationCat each annual inspectionDwhen the weight loss exceeds 10% of weight of charge

单选题The required number and type of hand portable fire extinguishers for staterooms on cargo vessels is().Aone A-IBone B-ICone C-IDnone required

单选题Which of the listed fire extinguishers is recommended for use on an electrical switchboard fire?()ACO2BABC dry chemicalCCO2 propelled foamDAll of the above

单选题All portable fire extinguishers must be capable of being().Acarried by hand to a fireBcarried or rolled to a fireCrecharged in the fieldDused on class 'B' fires

单选题Which types of portable fire extinguishers are designed for use on electrical fires?()ADry chemical and carbon dioxideBFoam (stored pressure) and soda-acidCCarbon dioxide and foam (stored pressure)DDry chemical and soda-acid

单选题Halon extinguishers used on a class C fire should be directed at the().Abase of the equipmentBtop of the equipmentCpower sourceDsource of the fire

单选题Halon from extinguishers used on a class B fire,should be directed().Aat the top of the flamesBat the base of the fire near the edgeCin short quick burstsDtoward the upwind side of the fire

单选题Each hand portable fire extinguisher on a ship must be marked with().Athe name of the unit on which it is locatedBthe date that it was installed on the unitCthe names of the individuals qualified to use itDan identification number different from other extinguishers on the unit

单选题Portable fire extinguishers must be provided for the cargo tank area of an unmanned tank barge().Aonly when fully loadedBif one or more tanks are fullCwhen transferring cargoDonly when the barge is being towed

单选题To determine the number of portable fire extinguishers required on an inspected vessel,you should check the().Ahot work permitBCertificate of InspectionCSafety of Life at Sea CertificateDMuster List

单选题Portable CO2 fire extinguishers should NOT be used to inert a space containing flammable liquids due to the danger of().Athe CO2 being inhaled by personnelBreflash of burning liquidsCvapor condensation on the extinguisherDthe discharge causing a static spark

单选题Each hand portable fire extinguisher must be marked with().Athe name of the vessel on which it is locatedBthe date that it was installedCthe names of the individuals qualified to use itDan identification number

单选题Which statement is TRUE concerning spare charges for portable fire extinguishers on unmanned tank barges?().ASpare charges shall be carried for at least 50 percent of each size and variety required on boardBIf the unit cannot be charged by the vessel's personnel,one spare unit shall be carried in lieu of spare chargesCSpare charges shall be stowed in watertight containers on deckDRegulations concerning spare charges do not apply to unmanned barges

单选题All portable fine extinguishers must be capable of being().Acarried by hand to a fireBcarried or rolled to a fireCrecharged in the fieldDused on class B fires