单选题On a Hardware Management Console (HMC) at version 7, an administrator has an LPAR defined with a minimum of 4GB of memory, 6GB desired and a maximum of 16 GB of memory. The administrator wants to go from 5 GB to 8 GB assigned memory for this partition. In order to make the change, what value should the administrator enter into the add processor resources window? ()A2 B3 C4 D8

单选题
On a Hardware Management Console (HMC) at version 7, an administrator has an LPAR defined with a minimum of 4GB of memory, 6GB desired and a maximum of 16 GB of memory. The administrator wants to go from 5 GB to 8 GB assigned memory for this partition. In order to make the change, what value should the administrator enter into the add processor resources window? ()
A

2 

B

3 

C

4 

D

8


参考解析

解析: 暂无解析

相关考题:

All client computers in your company run Windows 7 Enterprise. Each client computer runs one guest virtual machine (VM) in Windows Virtual PC .A user reports that a supported USB device connected to his client computer does not appear in the guest VM. The USB device functions correctly on the client computer.You need to ensure that the USB device can be installed in the guest VM.What should you do?()A.Use Virtual PC Manager to attach the USB device on the host.B.Run the Add Hardware Wizard in the guest.C.Use the Computer Management console to scan for hardware changes in the guest.D.Use the Computer Management console to update the USB Virtualization Bus driver on the host.

On a Hardware Management Console (HMC) at version 7, an administrator has an LPAR defined with a minimum of 4GB of memory, 6GB desired and a maximum of 16 GB of memory. The administrator wants to go from 5 GB to 8 GB assigned memory for this partition. In order to make the change, what value should the administrator enter into the add processor resources window? ()A、2 B、3 C、4 D、8

A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A、 To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B、 Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C、 Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD、 Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

An administrator wants to query the CPU resources of the managed system 9117-MMA*6512345 from the Hardware Management Console (HMC) command line.  Which of the following HMC commands could achieve this?()A、 lssysres -r cpu -m 9117-MMA*6512345 -r sysB、 lssyscfg -r proc -m 9117-MMA*6512345 -r sysC、 lshwres -r proc -m 9117-MMA*6512345 --level sysD、 lshwcfg -r proc -m 9117-MMA*6512345 --level sys

A Power Systems customer would like to upgrade their HMC to the latest version of software tosupport a new hardware feature. What resource will help identify dependencies for firmware and system software for their upgrade?()A、ITSO RedbooksB、Facts and FeaturesC、System Planning ToolD、Fix Level Recommendation Tool

Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A、 The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B、 The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C、 Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D、 Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

Prior to implementing an LPAR system, which of the following needs to be done?()A、A graphics monitor must be attached to the serverB、Cluster System Management (CSM) software must be installedC、The LPAR system must have an Hardware Management Console (HMC) connectedD、Each LPAR must be configured with a CDROM for operating system installation

An administrator needs to recover an HMC due to a failed disk. The disk has been replaced, allowing the administrator to reinstall the HMC back to the required release of software. Backups of both the HMC Console Data and Upgrade Data are available. After reloading the HMC with the Recovery DVDs, what are the next steps to restore the HMC configuration?()A、Use the 'HMC Management Restore HMC Data' option to first restore just the HMC Data..B、Use the 'HMC Management Restore Upgrade Data' option to first restore just the Upgrade Data.C、Use the 'HMC Management Restore HMC Data' option to first restore the HMC Data and then the Upgrade Data.D、Use the 'HMC Management Restore Upgrade Data' option to first restore the Upgrade Data, and then the HMC Data.

What does the "allow performance information collection" button do in the Hardware Management Console (HMC) GUI? ()A、 It allows you to get inter partition reports, or cross partition performance activity.B、 It will allow IBM remote technical support to get performance information from the machine.C、 It is effective only on POWER6 and when Live Partition Mobility operations are planned.D、 It will start standard performance monitoring tools when an LPAR boots up, the output will be saved to the /etc/perf directory by default.

Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems?()A、The systems must use internal storage for boot purposes. B、All virtualized ethernet adapters must be numbered below 10. C、The mobile partition's network and disk access must be virtualized. D、Each system must be controlled by a different Hardware Management Console (HMC).

A customer has a wide range of IBM enterprise disk systems and wants to manage copy services functions.  Which of the products should the storage specialist recommend to this customer()A、DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage serversB、Tivoli Storage Productivity Center for Data, because it manages ESS 800, DS6000, DS8000, and SVC storage serversC、Tivoli Storage Productivity Center for Replication, because it manages ESS 800, DS6000, DS8000, and SVC storage serversD、External DS Hardware Management Console (HMC), because it manages ESS 800, DS6000, DS8000, and SVC storage servers

On a Hardware Management Console (HMC) at version 7, an administrator has an LPAR defined with a minimum of 0.1 processors and a maximum of 4 processors. The administrator wants to go from 1 processing unit to 3 processing units for this partition. In order to make the change,  what value should the administrator enter into the add processor resources window? ()A、 2B、 3C、 1.0D、 2.9

Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()A、Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. B、The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. C、If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. D、The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot.

Which of the following interfaces is required to implement Workload Partition Mobility? ()A、 Workload Partitions Manager for AIXB、 Hardware Management Console (HMC) GUIC、 Integrated Virtualization Manager (IVM)D、 Advanced System Management Interface (ASMI)

Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A、 It has a GUI interface for upgrading system firmware. B、 It creates and manages AIX/Linux and VIOS type LPARs. C、 It can be managed by the Hardware Management Console (HMC). D、 It supports Live Partition Mobility on POWER6 systems and above.

All client computers in your company run Windows 7 Enterprise. Each client computer runs one guest virtual machine (VM) in Windows Virtual PC . A user reports that a supported USB device connected to his client computer does not appear in the guest VM. The USB device functions correctly on the client computer. You need to ensure that the USB device can be installed in the guest VM. What should you do?()A、Use Virtual PC Manager to attach the USB device on the host.B、Run the Add Hardware Wizard in the guest.C、Use the Computer Management console to scan for hardware changes in the guest.D、Use the Computer Management console to update the USB Virtualization Bus driver on the host.

单选题Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()ACards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. BThe HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. CIf the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. DThe Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot.

单选题On a Hardware Management Console (HMC) at version 7, an administrator has an LPAR defined with a minimum of 4GB of memory, 6GB desired and a maximum of 16 GB of memory. The administrator wants to go from 5 GB to 8 GB assigned memory for this partition. In order to make the change, what value should the administrator enter into the add processor resources window? ()A2 B3 C4 D8

单选题Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A It has a GUI interface for upgrading system firmware. B It creates and manages AIX/Linux and VIOS type LPARs. C It can be managed by the Hardware Management Console (HMC). D It supports Live Partition Mobility on POWER6 systems and above.

单选题In order for DLPAR operations to be possible, the RMC daemons on the Hardware Management Console (HMC) must communicate with the RMC daemons on all of the LPARs involved. How can the RMC daemons be restarted on the HMC, causing the least disruption?()ARun /usr/sbin/rsct/bin/rmcctrl z as hscroot. BReboot the HMC, either through the GUI or via the command line. CDisable and re-enable RMC in the Firewall settings in the HMC GUI. DSelect the Partition Communication checkbox in the LAN Adapter dialogue box.

单选题An administrator wants to query the CPU resources of the managed system 9117-MMA*6512345 from the Hardware Management Console (HMC) command line.  Which of the following HMC commands could achieve this?()A lssysres -r cpu -m 9117-MMA*6512345 -r sysB lssyscfg -r proc -m 9117-MMA*6512345 -r sysC lshwres -r proc -m 9117-MMA*6512345 --level sysD lshwcfg -r proc -m 9117-MMA*6512345 --level sys

单选题The administrator wants to backup the existing VIO server software and its current configuration before applying an update.  What command will the administrator use to backup the VIO server software so that the backup can be restored from a Network Installation Manager (NIM) server or a Hardware Management Console (HMC)?()A mksysb -t vio /mountpointB backupios -file /mountpointC mksysb -i /mountpoint/vio.mksysbD backupios -mksysb -file /mountpoint/vio.mksysb

单选题Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

单选题Which of the following interfaces is required to implement Workload Partition Mobility? ()A Workload Partitions Manager for AIXB Hardware Management Console (HMC) GUIC Integrated Virtualization Manager (IVM)D Advanced System Management Interface (ASMI)

单选题Prior to implementing an LPAR system, which of the following needs to be done?()AA graphics monitor must be attached to the serverBCluster System Management (CSM) software must be installedCThe LPAR system must have an Hardware Management Console (HMC) connectedDEach LPAR must be configured with a CDROM for operating system installation

单选题What does the "allow performance information collection" button do in the Hardware Management Console (HMC) GUI? ()A It allows you to get inter partition reports, or cross partition performance activity.B It will allow IBM remote technical support to get performance information from the machine.C It is effective only on POWER6 and when Live Partition Mobility operations are planned.D It will start standard performance monitoring tools when an LPAR boots up, the output will be saved to the /etc/perf directory by default.

单选题A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from