单选题Scale accumulation on evaporator heat exchange surfaces ().Aincreases brine densityBincreases distillate salinityCreduces metal corrosionDreduces heat transfer
单选题
Scale accumulation on evaporator heat exchange surfaces ().
A
increases brine density
B
increases distillate salinity
C
reduces metal corrosion
D
reduces heat transfer
参考解析
解析:
暂无解析
相关考题:
CSometimes, the simplest ideas are the best. For example, to absorb heat from the sun to heat water, you need large, flat, black surfaces. One way to do that is to build those surfaces specially, on the roofs of buildings. But why go to all that trouble when cities are full of black surfaces already, in the form. of asphalt (柏油) roads?Ten years ago, this thought came into the mind of Arian de Bondt, a Dutch engineer. He finally persuaded his boss to follow it up. The result is that their building is now heated in winter and cooled in summer by a system that relies on the surface of the road outside.The heat-collector is a system of connected water pipes. Most of them run from one side of the street to the other, just under the asphalt road. Some, however, dive deep into the ground.When the street surface gets hot in summer, water pumped through the pipes picks up this heat and takes it underground through one of the diving pipes. At a depth of 100 metres lies a natural aquifer (蓄水层) into which several heat exchangers (交换器) have been built. The hot water from the street runs through these exchangers, warming the ground-water, before returning to the surface through another pipe. The aquifer is thus used as a heat store.In winter, the working system is changed slightly. Water is pumped through the heat exchangers to pick up the heat stored during summer. This water goes into the building and is used to warm the place up. After performing that task, it is pumped under the asphalt and its remaining heat keeps the road free of snow and ice.64. Which of the following is true according to the first two paragraphs?A. Arian de Bondt got his idea from his boss.B. Large, flat, black surfaces need to be built in cities.C. The Dutch engineer's system has been widely used.D. Heat can also be collected from asphalt roads.
If the coolant temperature of a closed cooling water system for a diesel enginegradually increases, the trouble usually is( ).A.a broken shaft on the freshwater pumpB.an excessive accumulation of scale in the heat exchangerC.an incorrect thermostatic element operating rangeD.lube oil in the cooling water
The temperature of the refrigerant in the evaporator coil depends mostly upon the ___.A.refrigerant pressure in the evaporatorB.cooling water temperature to the condenserC.heat load in the refrigerator compartmentD.solenoid valve in the liquid line
第二组The only attention that heat exchanger should require is to ensure that the heat transfer surfaces remain substantially clean and the flow passages generally clear of obstruction. Indication that undue fouling is occurring is given by a progressive increase in the temperature difference between the two fluids, over a period of time, usually accompanied by a noticeable rise in pressure loss at a given flow.Fouling on the sea-water side is the most usual cause of deterioration in performance. The method of cleaning the sea water-side surfaces depends on the type of heat exchanger. With shell-and-tube heat exchangers, the removal of the header covers or, m the case of the smaller heat exchangers, the headers themselves, will provide access to the tubes. Obstructions, dirt, scale etc., can then be removed, using the tools provided by the heat exchanger manufacturer. Flushing through with fresh water is recommended before a heat exchanger is returned to service. In some applications, such as piston oil cooling, progressive fouling may take place on the outside of the tubes. Most manufactures recommend a chemical flushing pr6cess to remove this in situ~ without dismantling the heat exchanger.Plate heat exchangers may be cleaned by unclamping the stack of plates and mechanically cleaning the surface of each plate as recommended by the manufacturers. The plate seals may require replacement from time to time and here the manufacturers instructions should be closely followedBy which of the following indication, can we conclude that the lube oil-sea water heat exchanger is unduly fouled?A.the heat exchanger lube oil inlet temperature loweringB.the heat exchanger sea-water outlet pressure riseC.the heat exchanger temperature difference between lube oil and sea water increasingD.the heat exchanger pressure difference between sea water inlet and outlet decreasing
According to the passage, which of the following statement is not true?A.the heat exchanging surfaces should be kept substantially cleanB.the heat exchanger flow passages should be clear of obstructionC.seals for the plate heat exchanger needs to be renewed oftenD.the cleaning process of the plate heat exchanger should be done following our experiences only
The heat gained per pound of refrigerant in the evaporator is known as the ______.A.latent heat of vaporizationB.sensible heatC.refrigerating effectD.specific heat of vaporization
An increase in the heat load to a refrigeration system will cause ______.A.the suction pressure to decreaseB.the suction temperature to increaseC.increased ice formation on the evaporator coilD.excessive short cycling of the compressor
When compared to a high-expansion foam,a low-expansion foam will ______.A.Be dryerB.Be lighterC.Be less heat resistantD.Not cling to vertical surfaces
单选题Excessive scale formation in a distilling plant may result from ().Apoor distillate qualityBreduced evaporator capacityClow brine concentrationDimproper vacuum regulation
单选题The flash-evaporator is different with the submerged-tube evaporator in that for the former()AWater is heated into vapor on heating surfacesBWater is vaporized by pressure differenceCThere are no heating-transfer surfacesDThere are more heating-transfer surfaces
单选题The refrigerant flows through the evaporator, where it () heat from the refrigerated space.AextractsBreleasesCgives noDabsorbs no
单选题Improper cooling of a diesel engine cylinder liner due to the accumulation of scale deposits may cause ().Alow compression pressureBincreased piston wearCincreased cylinder lube oil consumptionDpoor contact between compression rings and liner
单选题The scale trap is located between the ()Aking valve and the expansion valveBsolenoid valve and expansion valveCevaporator and receiverDcompressor and evaporator
单选题Waterside scale in a fire-tube boiler may cause ().Aincreased heat transferBfireside erosionChigh steam demandDoverheated tubes
单选题The heat gained per pound of refrigerant in the evaporator is known as the().Alatent heat of vaporizationBsensible heatCrefrigerating effectDspecific heat of vaporization
单选题Less scale formation occurs in a flash evaporator than in a submerged tube evaporator because ().Athe distillate produced has greater purityBno boiling occurs on heat transfer surfacesCevaporation occurs at a higher rateDthe incoming feed is at a higher temperature
单选题Scale accumulation on evaporator heat exchange surfaces ().Aincreases brine densityBincreases distillate salinityCreduces metal corrosionDreduces heat transfer
单选题Which of the conditions listed represents the greatest effect of excess frost accumulation on the evaporator coils?()AKeeps the refrigerated space coolerBReduces the efficiency of the plantCTakes the load off the compressorDHas no affect on the system
单选题In a flash evaporator, scale as a result of higher than normal temperatures in most likely to occur in the ()Asecond stage feed heaterBsaltwater feed heaterCdistillate coolerDsecond stage vapor separator
单选题Fins are installed on the generating tube surfaces in waste heat boilers to ().Aprevent soot fires in the exhaust systemBprevent exhaust gas erosion of the tubesCincrease the velocity of exhaust gas flowDincrease the rate of heat transfer
单选题On which of the following heated surfaces of a flash type evaporator would you be more likely to find soft scale formation?()AFeed-water heater internal tube surfacesBInternal distillate cooler tubesCFlash chamber vertical surfacesDDistilling condenser tubes
单选题Scale and dirt accumulation in the waterside of a lube oil cooler will be indicated by a gradual increase in the lube oil().ATBN numberBviscosityCtemperatureDfoaming
单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor
单选题In a flash distilling unit, evaporator feed (seawater) first absorbs heat in the ().Avapor feed heaterBair ejector condenserCsaltwater heaterDdistillate cooler
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces
单选题Sacrificial zinc anodes are used on the saltwater side of diesel engine heat exchangers to().Areduce electrolytic action on heat exchanger metalsBkeep heat transfer surfaces shiny and cleanCprevent rapid accumulation of marine growthDprovide a protective coating on heat exchanger surfaces
填空题El Nino effect may become more frequent and fierce if enough heat could be brought to Pacific waters by the accumulation of greenhouse gases.____