A customer is looking to add disk storage. They are not satisfied with their existing EMCCLARiiON CX4-240. Instead of adding storage to the CX4, the customer wants to add a newsystem and migrate the LUNs from the EMC to the new storage system over a 6 month period,and not have any system disruption during this time. They are also interested in consolidating diskstorage management. Given these specifications, which of the following solutions would satisfythis customer’s requirements?()A、DS5100 and SAN Volume ControllerB、DS5100 and Tivoli Storage ManagerC、2 DS5100 systems with Remote MirroringD、DS5100 and Tivoli Storage Productivity Center for Data

A customer is looking to add disk storage. They are not satisfied with their existing EMCCLARiiON CX4-240. Instead of adding storage to the CX4, the customer wants to add a newsystem and migrate the LUNs from the EMC to the new storage system over a 6 month period,and not have any system disruption during this time. They are also interested in consolidating diskstorage management. Given these specifications, which of the following solutions would satisfythis customer’s requirements?()

  • A、DS5100 and SAN Volume Controller
  • B、DS5100 and Tivoli Storage Manager
  • C、2 DS5100 systems with Remote Mirroring
  • D、DS5100 and Tivoli Storage Productivity Center for Data

相关考题:

A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance.Which of the following actions should be recommended as a first step?()A. install the Performance Accelerator featureB. review the DS Storage Manager Major Event Log (MEL)C. add an expansion frame with additionalFibre Channel portsD. review the latest TPC for Disk study to identify the source of the performance issue

The customer has recently installed a pSeries p5-570 with EMC attached disk storage.  After installation, the customer complained that the disk access appeared to be too slow.  How should the pSeries technical specialist best assist the customer?()A、Recommend the customer call EMC.B、Recommend the customer call IBM hardware support.C、Recommend the customer contact SupportLine.D、Recommend the customer re-creates the volume groups.

A customer has an IBM System Storage Enterprise Storage Server and several EMC CX3 systems installed in a data center, attached to IBM System p servers. As a step toward data consolidation, they intend to put all data on a new DS8700.  What would be the most important data migration factors to consider()A、sector size and the amount of production dataB、existing RAID levels and the disk drive speedC、sector size and existing RAID levelsD、amount of production data and the disk drive speed

A customer wants to migrate their existing cluster onto new POWER6 hardware, and in addition requires thecluster to be migrated from PowerHA version 5.3 to 5.5. Given that AIX 6.1 and PowerHA 5.5 filesets arealready installed in the new hardware, which of the following methods would allow the customer to maintaintheir current cluster configuration?()A、Add the new nodes to the existing cluster, and perform a rolling migration and remove the original nodesfrom the clusterB、Add the new nodes to the existing cluster, and perform a non-disruptive upgrade and remove the originalnodes from the cluster.C、Create a snapshot of the existing cluster and apply the snapshot to the new cluster. Start cluster serviceson the new cluster and stop the original clusterD、Create a snapshot of the existing cluster and apply the snapshot to the new cluster. Stop cluster serviceson the original cluster and start on the new cluster

An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

A customer wants to add a new application to their existing IBM System Storage DS5300. Theyexpect that the new application will require a minimum of 15,000 additional IOPS. What toolshould be used to determine what additional disk is required to effectively add the newapplication?()A、eConfigB、Disk MagicC、Capacity MagicD、Tivoli Storage Productivity Center for Data

A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()A、add twofibre HBAs to the System i and connect to the SANB、add twofibre HBAs to the System i and connect to the Windows ServersC、add twofibre HBAs to the System i and connect to the System i using VIOSD、add two SAS HBAs to the Systemi array and connect directly to the DS5300

A customer wants to integrate an x445 running SuSE with their existing EMC storage infrastructure.  Which of the following tasks needs to be done to ensure that the solution will work properly?()A、Ensure that the EMC storage is listed on the IBM Server Proven websiteB、Ensure that the x445 is listed on the EMC Hardware Compatibility websiteC、Ensure that the x445 and the EMC storage server are listed on Novell’s SuSE Supported Hardware websiteD、Build a proof of concept system at the customer site to demonstrate functionality

A customer server has the maximum local storage installed. The customer plans to share this new storage with other servers. Which of the following provides that server additional storage?()A、Add External Storage via EXP3000B、Replace current storage with more dense drivesC、Add External Storage via SAND、Add storage expansion blade

A customer has installed an IBM System Storage DS8700 with 20 TB of storage, two-way processor version, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues.  To address this performance consideration with minimal cost to the customer, which of the following should be the FIRST step to resolve the problem()A、add an expansion frame with additionalFibre Channel portsB、increase the amount of storage by 20 TBC、conduct a Disk Magic study to identify the source of the performance issueD、add additionalFibre Channel ports to the existing DS8700

A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance. Which of the following actions should be recommended as a first step?()A、install the Performance Accelerator featureB、review the DS Storage Manager Major Event Log (MEL)C、add an expansion frame with additionalFibre Channel portsD、review the latest TPC for Disk study to identify the source of the performance issue

A mainframe customer wants to add additional disk capacity to an IBM System Storage DS8100to accommodate a projected workload increase. They ask the storage specialist to assess theimpact of the additional capacity on the DS8100 without other upgrades. Which tool bestassesses the impact of the upgrade on response times?()A、Capacity MagicB、TPC for DiskC、RMF disk reportsD、Disk Magic

Company.com is migrating from a third party managed disk subsystem to an IBM TotalStorage Enterprise Storage Server. Connection of the new storage server is complete, and it has been tested on all of the nodes in the three node HACMP cluster.  How does the customer migrate to the new storage server with minimum down time?()A、 Shut down one node at a time and let the other node serve the applicationB、 Stop HACMP with the forced option and perform migration of the disks on one node,then restart HACMPC、 Stop both nodes and perform the migration all at once using standard AIX commands in parallel, then restart the clusterD、 Use C-SPOC to add the new disks to the cluster and migrate the information off the existing disks, then remove the old disks with C-SPOC

A customer has 6.5 TB with 146 GB 15k disk drives on an IBM System Storage DS8700. They want to add 15 TB using 300 GB 15k disk drives. The customer is concerned about performance and wants to know if the DS8700 has the performance capability.  What is the appropriate way to  model the performance()A、Disk MagicB、Capacity MagicC、test the workload at an IBM Benchmark CenterD、test the solution with IBM Storage Performance Center

A customer wants to improve the utilization of the current capacity of their existing N series Tier 1production storage. What solution would the storage specialist discuss with the customer?()A、 compression with IBM Real-time Compression Appliances B、 deduplication with IBM ProtecTIER C、 virtualization with IBM SVC D、 file virtualization with SONAS

The customer has an older storage array and is looking to migrate data that currently exists onover 100 73 GB FC drives to a new IBM System Storage DS5020. The customer states that theyhave only 3 TB of data and wants to consolidate on to fewer higher capacity drives. There are sixapplication servers running multiple applications and operating systems utilizing the storagesystem. What would be the next step to accurately identify the new storage configuration?()A、initiate a Disk Magic studyB、initiate a Capacity Magic studyC、runiometer on the current environmentD、utilize the IBM Disk capacity planner toolkit

A customer has an existing high availability SAN environment with CLARiiON, which has been stable for 16 months. They have recently experienced several outages with their current storage systems. They need to purchase additional storage and have asked about tier 1 storage. They are concerned with connecting their existing storage and servers without trouble. Which resource should be consulted while developing the solution options?()A、Disk MagicB、TPC for DataC、CLARiiON Procedure GeneratorD、System Storage Interoperability Center

A mainframe customer has requested a proposal to replace an existing storage system. Which information does Disk Magic provide?()A、logical volume sizesB、cache usage by applicationC、storage processor utilizationD、disk capacity needed forFlashCopy

A customer with three Windows servers wants to create a shared storage array. One server runs a200 GB Oracle database with high transaction rates. The second server is a file server with 3 TBof data and the third server is a mail server with 150 GB of storage. The key customer decisionmaker has only purchased EMC CX storage products in his previous employment. Cost is a keyconsideration. From the following which is a key feature that could convince the customer topurchase a DS3500 over an EMC CX storage system?()A、 SATA and SAS 2.0 disk drive technology can be mixed in different enclosures B、 nearline SAS 2.0 and SAS 2.0 disk drive technology can be mixed in the same enclosureC、 SATA disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution D、 SAS 2.0 disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution

Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()A、The customer is looking for a fibre SAN solution to increase reliability and performance.B、The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.C、The customer is cost-conscious and is looking for a centralized storage solution.D、The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.

Your database is configured on non-ASM disk storage. You need to migrate your database to ASM disk storage.  Which statement is true about migrating from non-ASM disk storage to ASM disk storage?() A、 You can use the operating system utility to migrate from non-ASM disk storage to ASM disk storage.B、 You cannot perform a database backup from non-ASM disk storage to tape and then move it to ASM disk storage.C、 You can use the SWITCH DATABASE TO COPY Recovery Manager (RMAN) command to switch back to non-ASM disk storage if you have not deleted your original datafiles.D、 You cannot use Recovery Manager (RMAN) to migrate from non-ASM disk storage to ASM disk storage if you are not using RMAN for your backup and recovery strategies.

单选题A mainframe customer wants to add additional disk capacity to an IBM System Storage DS8100to accommodate a projected workload increase. They ask the storage specialist to assess theimpact of the additional capacity on the DS8100 without other upgrades. Which tool bestassesses the impact of the upgrade on response times?()ACapacity MagicBTPC for DiskCRMF disk reportsDDisk Magic

单选题A customer has 6.5 TB with 146 GB 15k disk drives on an IBM System Storage DS8700. They want to add 15 TB using 300 GB 15k disk drives. The customer is concerned about performance and wants to know if the DS8700 has the performance capability.  What is the appropriate way to  model the performance()ADisk MagicBCapacity MagicCtest the workload at an IBM Benchmark CenterDtest the solution with IBM Storage Performance Center

单选题Your database is configured on non-ASM disk storage. You need to migrate your database to ASM disk storage.  Which statement is true about migrating from non-ASM disk storage to ASM disk storage?()A You can use the operating system utility to migrate from non-ASM disk storage to ASM disk storage.B You cannot perform a database backup from non-ASM disk storage to tape and then move it to ASM disk storage.C You can use the SWITCH DATABASE TO COPY Recovery Manager (RMAN) command to switch back to non-ASM disk storage if you have not deleted your original datafiles.D You cannot use Recovery Manager (RMAN) to migrate from non-ASM disk storage to ASM disk storage if you are not using RMAN for your backup and recovery strategies.

单选题Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()AThe customer is looking for a fibre SAN solution to increase reliability and performance.BThe customer wants to implement an energy-efficient solution to comply with their Go Green initiative.CThe customer is cost-conscious and is looking for a centralized storage solution.DThe customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.

单选题A customer wants to add a new application to their existing IBM System Storage DS5300. Theyexpect that the new application will require a minimum of 15,000 additional IOPS. What toolshould be used to determine what additional disk is required to effectively add the newapplication?()AeConfigBDisk MagicCCapacity MagicDTivoli Storage Productivity Center for Data

单选题Company.com is migrating from a third party managed disk subsystem to an IBM TotalStorage Enterprise Storage Server. Connection of the new storage server is complete, and it has been tested on all of the nodes in the three node HACMP cluster.  How does the customer migrate to the new storage server with minimum down time?()A Shut down one node at a time and let the other node serve the applicationB Stop HACMP with the forced option and perform migration of the disks on one node,then restart HACMPC Stop both nodes and perform the migration all at once using standard AIX commands in parallel, then restart the clusterD Use C-SPOC to add the new disks to the cluster and migrate the information off the existing disks, then remove the old disks with C-SPOC