Which command would you use to enable chassis cluster on an SRX device, setting the cluster ID to 1 and node to 0?() A. user@host# set chassis cluster cluster-id 1 node 0 rebootB. user@host set chassis cluster id 1 node 0 rebootC. user@host set chassis cluster cluster-id 1 node 0 rebootD. user@host# set chassis cluster id 1 node 0 reboot

Which command would you use to enable chassis cluster on an SRX device, setting the cluster ID to 1 and node to 0?()

A. user@host# set chassis cluster cluster-id 1 node 0 reboot

B. user@host> set chassis cluster id 1 node 0 reboot

C. user@host> set chassis cluster cluster-id 1 node 0 reboot

D. user@host# set chassis cluster id 1 node 0 reboot


相关考题:

When configuring a single SRX210 as a firewall enforcer to a MAG4610 active/passive cluster, which statement supports a fault-tolerant configuration?() A. The cluster VIP is defined on the MAG4610 cluster, and the VIP of the cluster is defined as an instance on the SRX Series device.B. The cluster VIP is not defined on the MAG4610 cluster, and the IP address of both the active and passive nodes of the cluster are defined as separate instances on the SRX Series device.C. The cluster VIP is defined on the MAG4610 cluster, and the IP address of the active node is defined as an instance on the SRX Series device.D. The cluster VIP is not defined on the MAG4610 cluster, and the IP address of the passive node is defined as an instance on the SRX Series device.

通常长条状的Cluster相对于按蜂窝形状划分的Cluster更为常见。( )

Thesnmpinfocommandcanbesuedtoobtaininformationaboutthecurrentstateofarunningcluster.WhichofthefollowingwillprovideanadministratorwithacompletelistofinformationfromtheclusterMIB?() A.snmpinfo-mget-o/usr/es/sbin/cluster/hacmp.defs-vclusterB.snmpinfo-mdump-o/usr/es/sbin/cluster/hacmp.defs-vclusterC.snmpinfo-mget-o/usr/es/sbin/cluser/hacmp.defs-vclusterState.0D.snmpinfo-mdump-o/usr/es/sbin/cluster/hacmp.defs-vclusterState.0

Ifakill-9isperformedontheclstrmgrESprocess,thedefaultactionistohaltthesystem.Tochangethedefaultactiontodosomethingotherthenhaltingthesystem,whichofthefollowingfilesmustbemodified?() A./usr/es/sbin/cluster/etc/clexit.rcB./usr/es/sbin/cluster/etc/hacmp.termC./usr/es/sbin/cluster/etc/rc.clusterD./usr/es/sbin/cluster/etc/rc.shutdown

Acustomersynchronizestheclusterinavirtualizedenvironment.Duringtheprocessthefollowingwarningisdisplayed:FornodeswithasingleNetworkInterfaceCardperlogicalnetworkconfigured,itisrecommendedtoincludethefile’/usr/es/sbin/cluster/netmon.cf’withapingableIPaddressasdescribedinthePowerHAPlanningGuide.Whatshouldthecustomerdonext?()A.Ignorethewarningassynchronizationcompletedsuccessfully.B.Populatethe/usr/es/sbin/cluster/netmon.cffilewithoneormanyIPaddressesexternaltothecluster.C.Createanothervirtualadapteroneachnodeandset-upPowerHAnetworkinginamoretraditionalfashionD.Populatethe/usr/es/sbin/cluster/netmon.cffilewithanyofthebootIPaddressesononeoftheotherclusternodes

AnadministratorisinstallingPowerHAfilesets,andthisclusterwillbecross-mountingfilesystemsusingNFSversion4.Whichadditionalfilesetisrequired?() A.bos.net.tcp.clientB.cluster.es.nfs.rteC.bos.nfsv4.server.rteD.cluster.es.nfs.server

AnadministratorwantstousetheonlineplanningworksheetsasanaidtoconfiguringaPowerHAcluster.WhichPowerHAfilesetwouldtheadministratorneedtoinstallinordertoobtainthistool?() A.cluster.es.hawB.cluster.es.worksheetsC.cluster.es.tools.worksheetsD.cluster.es.server.worksheets

AnadministratorwantstoinstallWebSMITonanodethatisnotpartofacluster.WhichPowerHAfilesetprovidesthisfunction?() A.cluster.sysmgt.wsmB.cluster.es.client.wsmC.cluster.es.server.websmD.cluster.sysmgt.websm.rte

下面关于Cluster_ID属性描述错误的是() A.Cluster_ID属性是用来防止AS内部的环路B.Cluster_ID属性是可选过渡属性C.Cluster_ID属性是由路有反射器产生的,描述了一条路由所经过的反射器路径D.Cluster_List只在AS内部传播,从EBGP对等体收到的含有Cluster_List的路由将被丢弃