C3I system for Air Defense 即为防空C3I系统,下列哪一项不是其中之一:()A、指挥B、控制C、通信D、侦察

C3I system for Air Defense 即为防空C3I系统,下列哪一项不是其中之一:()

  • A、指挥
  • B、控制
  • C、通信
  • D、侦察

相关考题:

What is the function of the after-coolers installed in the diesel engine air intake system?A.Decrease the air densityB.Increase the exhaust temperatureC.Decrease the lube oil temperatureD.Increase the air density

第二组Under normal operation, some lubrication oil mist may be discharged from the air compressor to the air start system. This oil may be from excess compressor cylinder lubrication, from faulty oil scraper rings, or may even be suspended oil vapor contaminating the engine room atmosphere and drawn in at the compressor suction. Oil discharge is kept to a minimum by draining the after cooler, air receiver and starting system. If small quantities of lubrication oil do get passed into the starting air system, they will deposit as thin moist film over internal pipe surfaces but are not readily combustible. If a cylinder non-return valve leak while the engine is in operation, some hot gas, possibly with unburned fuel and cylinder lubrication oil, may be blown through the valve to the adjacent air manifold. With further heating from the leaky valve, this, together with the already deposited oil film, will carbonize and form. incandescent carbon. If starting air is applied to the system while still hot, the high pressure air coming into contact with the burning carbon may cause an explosion. Such an explosion will cause a flame to pass back through the air start pipe system, evaporating the deposited oil film and igniting it in the presence of air. Very high velocities and shockwaves are generated which may rupture pipes and fittings.Alternatively, if excessive oil has entered the air start system, a mixture of air and oil droplets may be discharged through the open cylinder non-return valve during starting. This spray may ignite due to high temperatures in the cylinder, causing a flame through the still open valve to the air manifold.To prevent an explosion, air start valves must be correctly maintained and lubricated to ensure correct timing and free movement with positive closing. Oil in the system must be kept to a minimum, pipe lines must be drained and cleaned internally when necessary and oil discharge from air compressors must be kept to a minimum by good maintenance.The passage is mainly aboutA.crankcase explosionB.scavenge box fireC.starting air pipeD.the danger of explosion in the starting air system

Air cocks, usually positioned at the_______in a circulating system, is used to get rid of the air in the system.A.bending jointB.expansion tankC.weldD.the highest point

Restrictions occurring in the small orifices(孔) of pneumatic control system components can be caused by ______.A.moisture in the compressed air supplyB.excessive dryness in the compressed air supplyC.pressure surging in the compressed air receiverD.insufficient lubrication of the system components

In an air conditioning system, moisture is removed from the air by ______.A.filtersB.separatorsC.ducted trapsD.dehumidifiers

The“three arms of government” of Australia refers to the Parliament,the Executive Government and( ) A.the Judiciary B.the High Court C.the Defense Force D.the Air Force

C3I的内容是什么?C3I的系统设备与结构是什么?

《人民防空工程设计防火规范》规定,人民防空工程即为保障人民防空指挥、( )、掩蔽等需要而建造的防护建筑。A、通电B、通信C、通讯

单选题Air blowing from the intake air filter of an operating air compressor indicates ().Abroken inlet valvesBbroken discharge valvesCpulsations in the air distribution systemDoverloading of the air distribution system

单选题What is the function of an air receiver in the compressed air system on a ship? ()ACondenses moistureBProvides overpressure protectionCPurifies the airDActs as an accumulator

单选题In an air conditioning system, moisture is removed from the air by()AfilersBseparatorsCducted trapsDdehumidifiers

单选题A re-heater in an air conditioning system functions to ().Acontrol inlet air temperatureBcontrol inlet air volumeCmaintain relative humidity at 15%Drestore conditioned air temperature to a comfortable level

单选题For the proper control of the air temperature in an air conditioning system using chilled water circulation, which of the listed conditions should remain constant regardless of load changes?()AChilled water system supply temperatureBChilled water system return temperatureCCompressor discharge temperatureDCompressor suction pressure

单选题Restrictions occurring in the small orifices of pneumatic control system components can be used by ()Amoisture in the compressed air supplyBexcessive dryness in the compressed air supplyCpressure surging in the compressed air receiverDinsufficient lubrication of the system components

单选题Air cocks, usually positioned at the () in a circulating system, is used to get rid of the air in the system.Abending jointBexpansion tankCweldDthe highest point

单选题Diesel engine air start system check valves are opened by ()Aan air start camBcylinder compression pressureCstarting air pressureDvalve springs

单选题In the starting system, the automatic valve is controlled by(), and the cylinder start valves are controlled by()Apilot air;pilot airBhandle;solenoidChandle;pilot air coming through the distributorDsolenoid;pilot air coming through the distributor

单选题The primary task of the compressed air system is to deliver the starting air necessary for ()Astarting the MEBstarting the emergency electric alternatorCdriving the main turbineDdriving the turbocharger

判断题To keep the prosperity of the air industry, the Department of Defense has invested a lot of money to develop an innovative type of aircraft which does not need a runway.A对B错

单选题C3I system for Air Defense 即为防空C3I系统,下列哪一项不是其中之一:()A指挥B控制C通信D侦察

单选题If an air compressor is used to supply compressed air to outlets throughout the engine room and on deck of a vessel, the system is known as the ().Acombustion control air systemBsupply air systemCships service air systemDlow pressure deck air system

单选题Which of the following methods is normally used to control the temperature of air distributed from individual cooling coils in an air conditioning system using a chilled water circulation system?()AA room thermostat activates an electric heater at each individual chilled air outlet when necessaryBVarying the number of passes the air makes across the coilsCVarying the temperature of the water through the coilsDVarying the quantity of water flowing through the coils

单选题To prevent the unnecessary loading of an air conditioning system while maintaining the designed dry bulb temperature and relative humidity in an air conditioning system, you should ()Aadmit only enough fresh outside air to provide proper ventilationBreduce the air reheating system loadClower the compressor head pressureDoperate the purge recovery unit continuously

单选题As a defense against air-pollution damage, many plants and animals _____ a substance to absorb harmful chemicals.ArelieveBreleaseCdismissDdiscard

单选题Pump up the starting air reservoirs to their maximum pressure and ()the air reservoirs and air system.AopenBcloseCdrainDvent

单选题If an air compressor is used to supply air primarily to the combustion control system and other pneumatic controllers, the entire system is known as the ().Acontrol air systemBforced draft air systemCsupply air systemDships service air system

单选题What is the function of the after-cooler installed in the diesel engine air intakes system?()ADecrease the air densityBIncrease the exhaust temperatureCDecrease the lube oil temperatureDIncrease the air density