A p5-550 with AIX 5.3 is being designed for availability. In addition to providing redundant adapters, which of the following should also be provided?()A、Redundant processor pools, UPS, and HACMPB、Redundant service processors, HACMP, and mirrored AIX drivesC、Redundant processor pools, redundant service processors, and HACMPD、Redundant power, redundant Virtual I/O Servers, and mirrored AIX drives
A p5-550 with AIX 5.3 is being designed for availability. In addition to providing redundant adapters, which of the following should also be provided?()
- A、Redundant processor pools, UPS, and HACMP
- B、Redundant service processors, HACMP, and mirrored AIX drives
- C、Redundant processor pools, redundant service processors, and HACMP
- D、Redundant power, redundant Virtual I/O Servers, and mirrored AIX drives
相关考题:
A customer has budget sign-off to purchase a new p5-550 2-way server to replace their aging 2-way 7025-6F0. They like the advantages of the Simultaneous Multi Processing (SMT) ability of this server. Their application is certified at AIX 5.2 and is scheduled for AIX 5.3 certification in six months. The Chief Information Officer is concerned that they will lose the budget if they do not purchase the server this fiscal year. What is the most relevant and cost-effective advice the pSeries technical specialist can offer?()A、Purchase a 4-way p630 to compensate for not using SMT.B、Purchase the p5-550 server and install AIX 5.2, which can be upgraded to AIX 5.3 later.C、Purchase the p5-550 server and install AIX 5.2 and enable SMT.D、Suspend the purchase of a new machine at this time and upgrade the current server to a 4-way server.
A financial industry customer will consolidate their Intel-based servers to a p5-550 running AIX, and needs experienced technical services. What information should the account executive provide to the customer to assure them that the technical specialist has the required experience?()A、The technical specialist has supported multiple Cluster 1350 environments. References will be provided.B、The technical specialist is Linux-certified by two industry groups. Certificate copies will be provided.C、The technical specialist has worked on multiple UNIX consolidation projects. References will be provided.D、The technical specialist has worked on Linux consolidation efforts. References will be provided.
A customer wishes to replace 12 older small UNIX systems. They are running out of floor space in their data center and any solution must take this into consideration. Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()A、A p650 running AIX v5.3B、A p5-550 running AIX v5.3C、A p5-570 running Advanced POWER VirtualizationD、Multiple rack-mounted p615s running dynamic LPAR
A customer requires a 2-way solution now that will be the easiest and least disruptive to upgrade to a 4-way in the future. Which of the following solutions best matches these requirements?()A、p630 2-way Active 2-way InactiveB、p655 2-way Active 2-way InactiveC、p5-520 2-way Active 2-way InactiveD、p5-550 2-way Active 2-way Inactive
Company.com has recently added a partition to an existing p5-550 4-way with 8GB RAM. When the newly-created third partition is started, it fails to initialize. The configuration of the partitions is as follows: LPAR Min CPU Des CPU Max CPU P1 0.8 1.4 2.0 P2 0.8 1.4 2.0 P3 1.4 1.6 2.0 Which of the following actions will most likely resolve the problem?()A、Reduce P3 max CPU to 1.8B、Reduce min CPU on P3 to 1.2.C、Recommend the purchase of additional CPU.D、Ensure that partition 3 has a minimum of 4GB of memory.
A pSeries technical specialist is designing a p5-550 LPAR solution which will contain four logical partitions. Which tool should be used to ensure adherence to all partition rules?()A、LVTB、eSARC、eConfigD、PCRS6000
Company.com is running a p5-550 system with inactive processors. The system is managed using the Integrated Virtualization Manager. How would the system administrator activate two additional processors?()A、Use the Advanced Systems Management Interface to enter the Capacity on Demand Enablement code.B、Use the Web-based System Manager Interface to enter the Capacity on Demand enablement code.C、Use smitty or smit interface to enter the Capacity on Demand enablement code.D、Use oem_setup_env on the Virtual I/O Server to enter the Capacity on Demand enablement code.
A p5-570 8-way 32GB system has been proposed to a customer as a new test system with four LPARs. The current applications are certified on AIX 5.2 but not yet on AIX 5.3. The customer wants to understand the advantages and disadvantages of this solution versus a pair of 4-way p5-550s with 16GB each in testing their current applications. Which of the following points should the pSeries technical specialist highlight?()A、The p5-570 would save rack space over a pair of p5-550 servers.B、The p5-570 allows for more CPU and memory resources to be dynamically allocated to any LPAR for performance testing.C、The p5-570 can only be upgraded to 64GB of RAM without replacing memory.D、The p5-570 supports advanced features such as Micro-Partitioning and Virtual I/O allowing more LPARs of the customer’s applications with fewer processors and fewer I/O adapters.
A customer requires a deskside solution that they will rack-mount in the future. Space is at a premium. The solution must support two AIX 5.2 applications that require two processors each. Which of the following deskside configurations should the pSeries Technical Specialist recommend?()A、One p5-550 4-wayB、Two 2-way p5-520sC、One p630 4-wayD、Two 2-way p615s
A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future. Which pSeries system would be positioned best to meet this customer’s requirements?()A、p5-550 with the Advanced POWER Virtualization feature and AIX 5.2B、p5-550 with the POWER5 processor technology and AIX 5.2C、p5-570 with the Advanced POWER Virtualization feature and AIX 5.3D、p5-570 with the POWER5 processor technology and AIX 5.2
The Information Technology (IT) department wants to consolidate two 4-way p5-550 servers onto an 8-way p5-570. However, the departments using the p5-550 servers are concerned about quality of service after consolidation. Which per-partition processor allocation would provide comparable performance while still allowing the POWER5 hypervisor to optimize the processing workload of the server?()A、4.0 processing units, 4 virtual processors, capped modeB、4.0 processing units, 4 virtual processors, uncapped modeC、4.0 processing units, 8 virtual processors, capped modeD、4.0 processing units, 8 virtual processors, uncapped mode
Which of the following is required to connect a partitioned p5-550 to a modem?()A、A modem adapterB、An async adapter and serial cableC、An Ethernet adapterD、A 9-pin to 25-pin converter and serial cable
A space-constrained customer is currently running AIX 5.2 on a number of p650 servers and a pair of new p5-550 servers. They have four identical new applications each requiring a minimum of seven processors and 96GB of memory. Which solution would best meet the customer’s requirements?()A、Two p670 serversB、Four p650 serversC、Two p5-570 serversD、Four p5-550 servers
Which of the following steps should be done FIRST when deploying a Virtual I/O server on a p5-550, which will host three logical partitions: a NIM server and two application servers?()A、Create and install the NIM serverB、Create and install the Virtual I/O ServerC、Create and install the application serversD、Activate Advanced POWER Virtualization
Company.com has a 2 processor license for SLES 9 and a 2 processor license for AIX V5.3. Which of the following LPAR configurations is valid on a 4-way p5-550?()A、SLES9:2 dedicated processors AIX: 2.0 processing units,4 virtual processors,uncappedB、SLES9:2.0 processing units,2 virtual processors,uncapped AIX:2.0 processing units,4 virtual processors,cappedC、SLES9:2.0 processing units,3 virtual processors,uncapped AIX:2 dedicated processors SLES9:2.5 processing units,3 virtual processors,cappedD、AIX:1.5 processing units,2 virtual processors,capped
A customer needs an Oracle Database Server. Based on the customer’s sizing data, the IBM Oracle Competency Center has determined that the server requirements can be met with a 4-way p5-550 or a 4-way p5-570. If the pSeries technical specialist proposes a p5-570 versus a p5-550 system, what key differences should be pointed out to the customer?()A、The p5-570 is rack mounted but the p5-550 is not.B、The p5-570 will provide more growth, but at a higher cost.C、The p5-570 is 200-240 volt only and the p5-550 is 110 volt only.D、The p5-570 needs a special feature to become a deskside machine.
单选题The Information Technology (IT) department wants to consolidate two 4-way p5-550 servers onto an 8-way p5-570. However, the departments using the p5-550 servers are concerned about quality of service after consolidation. Which per-partition processor allocation would provide comparable performance while still allowing the POWER5 hypervisor to optimize the processing workload of the server?()A4.0 processing units, 4 virtual processors, capped modeB4.0 processing units, 4 virtual processors, uncapped modeC4.0 processing units, 8 virtual processors, capped modeD4.0 processing units, 8 virtual processors, uncapped mode
单选题A customer needs an Oracle Database Server. Based on the customer’s sizing data, the IBM Oracle Competency Center has determined that the server requirements can be met with a 4-way p5-550 or a 4-way p5-570. If the pSeries technical specialist proposes a p5-570 versus a p5-550 system, what key differences should be pointed out to the customer?()AThe p5-570 is rack mounted but the p5-550 is not.BThe p5-570 will provide more growth, but at a higher cost.CThe p5-570 is 200-240 volt only and the p5-550 is 110 volt only.DThe p5-570 needs a special feature to become a deskside machine.