During Company.com planning session, the discussion focuses on how the IP connections are  Managed after a cluster node failure. This is critical for the business since their production application is a Lotus Domino solution requiring multiple IP addresses and recovery time is critical.  What type of IPAT implementation would best address these requirements?()  A、 IPAT via IP aliasingB、 IPAT via IP replacementC、 IPAT via IP aliasing using HWATD、 IPAT via IP replacement using HWAT

During Company.com planning session, the discussion focuses on how the IP connections are  Managed after a cluster node failure. This is critical for the business since their production application is a Lotus Domino solution requiring multiple IP addresses and recovery time is critical.  What type of IPAT implementation would best address these requirements?()  

  • A、 IPAT via IP aliasing
  • B、 IPAT via IP replacement
  • C、 IPAT via IP aliasing using HWAT
  • D、 IPAT via IP replacement using HWAT

相关考题:

A customer has an IBM System Storage DS8700 and wants to reach the highest possible throughput in the back-end for a storage-pool-striped volume out of an extent pool with 8 ranks.  Over how many device adapter pairs should a technical specialist spread the workload()A、2B、4C、6D、8

Upon announcement,the specific details surrounding the Virtual I/O Server requirements and performance are still being defined.  The customer has engaged IBM to provide a server consolidation solution and would like to take advantage of the VIO Server benefits. How should the pSeries technical specialist best address this?()A、Design the solution and present it confidently so the customer does not question it.B、Design the solution and ensure the customer understands the unknowns with the new technology.C、Explain to the customer that the VIO Server does not benefit them when doing server consolidation so it has not been configured.D、Explain to the customer that the details surrounding the VIO Server have not been clearly defined so designing a solution is premature.

下面哪些关于SOA和Web服务的描述是正确的?()A、SOAP文档是XML格式的B、服务的接口是通过XML构造和发布的C、服务的查找可以通过UDDI进行D、服务的消息传递是基于SOAP的。

A cluster administrator has defined a custom error notification method that will email and  administrator when a temp error is detected on an individual hdisk. What method should be used to test this functionality?()  A、 sendmail -biB、 yes /dev/kmemC、 emulate errlog entryD、 reducevg vgname hdisk#

Which command is used to switch from AIX to the System V printing subsystem on AIX 5L Version 5.1?()A、 switch.prt -s AIX B、 switch.prt -s SystemV C、 switch.prt -d AIX D、 switch.prt -d SystemV

A financial industry customer will consolidate their Intel-based servers to a p5-550 running AIX, and needs experienced technical services.  What information should the account executive provide to the customer to assure them that the technical specialist has the required experience?()A、The technical specialist has supported multiple Cluster 1350 environments. References will be provided.B、The technical specialist is Linux-certified by two industry groups. Certificate copies will be provided.C、The technical specialist has worked on multiple UNIX consolidation projects.  References will be provided.D、The technical specialist has worked on Linux consolidation efforts.  References will be provided.

The IBM Maximo Asset Management V6.2 administrator creates a new Start Center with updated Key Performance Indicators.  Which application must be used to associate the Start Center to users? ()A、 UsersB、 PeopleC、 OrganizationsD、 Security Groups

Which of the following is a correct statement about rPerf?()A、It can only be used on systems running without partitions.B、It is relevant for IBM systems running the AIX operating system.C、It is the main benchmark for sizing systems that will run HPC applications.D、It has a direct relationship with other benchmarks like TPC-C and SpecjAppServer2004.

Which of the following steps should be done FIRST when deploying a Virtual I/O server on a p5-550, which will host three logical partitions: a NIM server and two application servers?()A、Create and install the NIM serverB、Create and install the Virtual I/O ServerC、Create and install the application serversD、Activate Advanced POWER Virtualization