单选题Fighting a rig fire in a watertight compartment with hoses could reduce the stability of the rig by().Aprogressive downfloodingBreducing the level of drill water from the storage tanksCcausing a list due to the water in the compartmentDreducing the KG to minimum allowable
单选题
Fighting a rig fire in a watertight compartment with hoses could reduce the stability of the rig by().
A
progressive downflooding
B
reducing the level of drill water from the storage tanks
C
causing a list due to the water in the compartment
D
reducing the KG to minimum allowable
参考解析
解析:
暂无解析
相关考题:
Lifesaving regulations require that a fire drill include ______.A.Starting the fire pumpsB.Checking the operation of watertight doorsC.Checking arrangements for abandon shipD.All of the above
During a fire drill on a vessel, what action is required? ______.A.Start each fire pump.B.Launch and run a lifeboat.C.Inventory rescue and fire equipment.D.Inspect fire hoses
Fire axes required on MV MODU’s must be stored in the enclosure for fire hoses with the location marked ______.A.Fire Axe LocationB.Hose Station No. …C.Fire Station No. …D.Firefighting Equipment
Where do you post your ()(火势控制图)?A、fire control planB、fire controlC、fire planD、fire-fighting plan
单选题If you are fighting a fire below the main deck of your vessel,which action is most important concerning the stability of the vessel?().AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题On a ship,watertight doors should be operated().Aduring abandon drillBduring fire drillCweeklyDwhen the rig is being moved
单选题What is the most vulnerable part of the fire main system on board an offshore rig?()AThe fire pumpBExposed hard pipingCThe hydrant valveDThe fire hose
单选题A foam-type portable fire extinguisher is most useful in fighting a fire in().AgeneratorsBoil drumsCthe bridge controlsDcombustible metals
单选题If you are fighting a fire below the main deck of your vessel,which action is most importantconcerning the stability of the vessel? ()AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题Lifesaving regulations require that a fire drill include().Astarting the fire pumpsBchecking the operation of watertight doorsCchecking arrangements for abandon shipDAll of the above
单选题A fire must be ventilated().Awhen using an indirect attack on the fire such as flooding with waterBto prevent the gases of combustion from surrounding the firefightersCto minimize heat buildup in adjacent compartmentsDif compressed gas cylinders are stowed in the compartment on fire
单选题Ventilation systems connected to a compartment in which a fire is burning are normally closed to prevent the rapid spread of the fire by().AconvectionBconductionCradiationDspontaneous combustion
单选题The bilge main is arranged to drain any watertight compartment () ballast, oil or water tanks and to discharge the contents overboard.Arather thanBother thanCin addition thatDexcept for
单选题When two fire hose teams are attacking a fire they should().Ause different fire hose pressuresBuse fire hoses of different sizesCnot attack the fire from opposite sidesDnot wear protective clothing
单选题Combustible material stored in a compartment adjacent to a compartment where there is a fire may be ignitedThis ignition can occur by ().Aheat convection through the adjacent bulkheadsBcombustion gases carried through the ventilation systemCdirect convection of the heat emitted by the adjacent fireDheat radiated from the dock or bulkhead by the adjacent fire
单选题Fighting a rig fire in the ballast pumproom with hoses would adversely affect the stability of the rig most by().Aincreasing the permeability of the pumproomBreduction of drill water from the storage tanksCa list caused by water filling the compartmentDa reduced KG caused by water filling the compartment
单选题A fire is considered "under control" when ().Aall hands are at their fire stationsBall fire-fighting equipment is at the sceneCthe fixed systems are activatedDthe fire is contained and no longer spreading
单选题Which fire detection system is actuated by sensing a heat rise in a compartment?()AManual fire detection systemBAutomatic fire detection systemCSmoke detection systemDWatchman's supervisory system
单选题It is necessary to secure the forced ventilation to a compartment where there is a fire to().Aallow the exhaust fans to remove smokeBextinguish the fire by carbon monoxide smotheringCprevent additional oxygen from reaching the fireDprotect fire fighting personnel from smoke
单选题During a fire drill on a vessel,what action is required?().AStart each fire pumpBLaunch aand run a lifeboatCInventory rescue and fire equipmentDInspect fire hoses
单选题During a fire drill on a ship,what action is required?()AStart each fire pumpBLaunch and run a lifeboatCInventory rescue and fire equipmentDInspect fire hoses
单选题Fire in an engine compartment is best extinguished with carbon dioxide gas (CO2) and by().Acompletely closing the compartmentBclosing the compartment except for the ventilatorsCleaving the compartment open to the airDincreasing the air flow to the compartment by blowers
单选题When fighting a fire with a portable dry chemical fire extinguisher,the stream should be directed().Aover the top of the flamesBoff a bulkhead into the fireCin front of the fireDat the base of the fire