单选题IBM hardware support has just replaced a disk, and commented that the system administrator might want to remove the "DISK OPERATION ERROR" from the error report. Which of the following commands is used to delete the "DISK OPERATION ERROR" from the following error report() IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION F89FB899 0616150005 P O dumpcheck The copy directory is too small. 5DFED6F1 0616075205 I O SYSPFS UNABLE TO ALLOCATE SPACE IN FILE SYSTEM AA8AB241 0615153905 T O OPERATOR OPERATOR NOTIFICATION 35BFC499 0412130605 P H hdisk6 DISK OPERATION ERROR 91FBD5DB 0525045805 P S ssa1 SOFTWARE PROGRAM ERROR 05F97A32 0525045805 P H ssa1 ADAPTER ERRORAerrclear -k 35BFC499 0Berrclear 35BFC499 00Cerrclear -j 35BFC499 0Derrclear 35BFC499 0
单选题
IBM hardware support has just replaced a disk, and commented that the system administrator might want to remove the "DISK OPERATION ERROR" from the error report. Which of the following commands is used to delete the "DISK OPERATION ERROR" from the following error report() IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION F89FB899 0616150005 P O dumpcheck The copy directory is too small. 5DFED6F1 0616075205 I O SYSPFS UNABLE TO ALLOCATE SPACE IN FILE SYSTEM AA8AB241 0615153905 T O OPERATOR OPERATOR NOTIFICATION 35BFC499 0412130605 P H hdisk6 DISK OPERATION ERROR 91FBD5DB 0525045805 P S ssa1 SOFTWARE PROGRAM ERROR 05F97A32 0525045805 P H ssa1 ADAPTER ERROR
A
errclear -k 35BFC499 0
B
errclear 35BFC499 00
C
errclear -j 35BFC499 0
D
errclear 35BFC499 0
参考解析
解析:
暂无解析
相关考题:
You are installing Windows 2000 Server on a new computer that has a single 10-GB SCSI disk. The disk controller is not included on the current Hardware Compatibility List (HCL). You start the computer by using the Windows 2000 Server CD-ROM.When the computer restarts at the end of the text mode portion of Windows 2000 setup, you receive the following STOP error: "INACCESSIBLE_BOOT_DEVICE."Which two actions should you take to eliminate the STOP error? (Choose Two)A.Restart the Windows 2000 Setup by using the Windows 2000 Server CD-ROM.B.Select Safe Mode from the Windows 2000 boot menu.C.Remove the Windows 2000 Server CD-ROM from the CD-ROM drive.D.Install a driver for the SCSI controller from a floppy disk.E.Use Device Manager to update the driver for the SCSI controller.
In a three-disk volume group, a disk was physically removed from the system without performing any software procedures to properly remove the disk. Which of the following commands should be performed to recover from this error?()A.extendvgB.cfgmgrC.reducevgD.varyoffvg
After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()A、Replace the second drive with a hot swappable one.B、Swap the drive boot order in the BIOSC、Make the second disk active under the disk management tool.D、Rebuild the array using the hardware RAID tool at boot.
A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()A、chvgB、rmdevC、reducevgD、exportvg
When attempting to boot a PC, the POST process completes without error. The PC then displays,‘non system disk or disk error’. Which of the following would MOST likely cause the issue?()A、Out-of-date BIOSB、Invalid motherboard jumper settingsC、Failing power supplyD、Floppy disk in the drive
In a three-disk volume group, a disk was physically removed from the system without performing any software procedures to properly remove the disk. Which of the following commands should be performed to recover from this error?()A、extendvgB、cfgmgrC、reducevgD、varyoffvg
A system administrator has a two-disk volume group (testvg) with one logical volume (testlv) which has just been mirrored across both disk drives. Which of the following commands can be used to turn off quorum?()A、chvg -Qn testvgB、chlv -Qn testlvC、varyoffvg testvg; varyonvg -Qn testvgD、varyoffvg testvg; exportvg testvg; importvg -Qn testvg; varyonvg testvg
Automatic error notification can be configured to manage which type of disk error?() A、 Hard errorsB、 Media errorsC、 Temporary errorsD、 All disk error types
A system administrator has determined a root mirrored disk, hdisk1, needs to be replaced. The root volume has been unmirrored. What is the next step to remove the disk drive?()A、cfgmgrB、rmdev -d hdisk1 -lC、reducevg rootvg hdisk1D、have the IBM CE replace the disk
Which of the following commands is used to clear all entries from the system error log? ()A、 errpt -c B、 errclear -j 0 C、 errclear 0 D、 startsrc -s syslogd
Which of the following commands should be used to determine which disk of a system is experiencing a disk I/O performance problem?()A、 filemonB、 istatC、 vmstatD、 iostat
Error log analysis indicates that a disk is starting to fail and will need to be replaced. The failing disk contains multiple logical volumes which span multiple disks. A free disk has been added to the failing disk’s volume group.Which of the following is the most efficient method to move the data from the failing disk to the new disk?()A、Back up the data, remove the failing disk from the volume group, then restore the data to the new disk.B、Use the migratepv command to move data from one disk to another and then remove the failing disk from the volume group.C、Use the mirrorvg command to mirror the data to the new disk, break the mirror and then remove the failing disk from the volume group.D、Create a new filesystem on the new disk and use the mv command to move the data to the new filesystem, and then remove the failing disk from the volume group.
During a system boot, an error message appears concerning a paging space, paging00. The paging space was located on hdisk2, but the disk was removed from the system without proper software procedures. Which of the following commands should be used as the first step in the process of recovery?()A、mkps paging00 hdisk0B、chpv -v r hdisk2C、chps -a n paging00D、reducevg rootvg hdisk2
What is the net effect of the following command?() alter diskgroup dgroup1 drop disk abc;A、 The disk ABC will be dropped from the disk group. Since you did not issue a rebalance command,the data on that disk will be lost.B、 The command will raise an error indicating that you need to rebalance the disk group to remove the data from that disk prior to dropping the disk.C、 The disk group will be automatically rebalanced during the drop operation. Once the rebalancing is complete,the disk will be dropped.D、 This command will fail because you cannot drop a specific disk in an ASM disk group.E、 The disk drop command will be suspended for a predetermined amount of time,waiting for you to also issue an alter diskgroup rebalance command. Once you have issued the rebalance command,ASM will proceed to rebalance the disk group and then drop the disk.
IBM hardware support has just replaced a disk, and commented that the system administrator might want to remove the "DISK OPERATION ERROR" from the error report. Which of the following commands is used to delete the "DISK OPERATION ERROR" from the following error report() IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION F89FB899 0616150005 P O dumpcheck The copy directory is too small. 5DFED6F1 0616075205 I O SYSPFS UNABLE TO ALLOCATE SPACE IN FILE SYSTEM AA8AB241 0615153905 T O OPERATOR OPERATOR NOTIFICATION 35BFC499 0412130605 P H hdisk6 DISK OPERATION ERROR 91FBD5DB 0525045805 P S ssa1 SOFTWARE PROGRAM ERROR 05F97A32 0525045805 P H ssa1 ADAPTER ERRORA、errclear -k 35BFC499 0B、errclear 35BFC499 00C、errclear -j 35BFC499 0D、errclear 35BFC499 0
单选题Automatic error notification can be configured to manage which type of disk error?()A Hard errorsB Media errorsC Temporary errorsD All disk error types
单选题During a system boot, an error message appears concerning a paging space, paging00. The paging space was located on hdisk2, but the disk was removed from the system without proper software procedures. Which of the following commands should be used as the first step in the process of recovery?()Amkps paging00 hdisk0Bchpv -v r hdisk2Cchps -a n paging00Dreducevg rootvg hdisk2
单选题When attempting to boot a PC, the POST process completes without error. The PC then displays,‘non system disk or disk error’. Which of the following would MOST likely cause the issue?()AOut-of-date BIOSBInvalid motherboard jumper settingsCFailing power supplyDFloppy disk in the drive
单选题After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()AReplace the second drive with a hot swappable one.BSwap the drive boot order in the BIOSCMake the second disk active under the disk management tool.DRebuild the array using the hardware RAID tool at boot.
单选题What is the net effect of the following command?() alter diskgroup dgroup1 drop disk abc;A The disk ABC will be dropped from the disk group. Since you did not issue a rebalance command,the data on that disk will be lost.B The command will raise an error indicating that you need to rebalance the disk group to remove the data from that disk prior to dropping the disk.C The disk group will be automatically rebalanced during the drop operation. Once the rebalancing is complete,the disk will be dropped.D This command will fail because you cannot drop a specific disk in an ASM disk group.E The disk drop command will be suspended for a predetermined amount of time,waiting for you to also issue an alter diskgroup rebalance command. Once you have issued the rebalance command,ASM will proceed to rebalance the disk group and then drop the disk.
单选题After executing the command alter diskgroup disk group2 drop disk dg2a; you issue the following command from the ASM instance: Select group_number, count(*) from v$asm_operation; What is the implication if the query against V$ASM_OPERATION returns zero rows?()A The drop disk operation is still proceeding and you cannot yet run the undrop disks operation.B The drop disk operation is complete and you can run the undrop disks command if needed.C The drop disk operation is complete and you cannot run the undrop disk command.D The query will fail since there is not a V$ASM_OPERATION view available in an ASM instance. E None of the above is true.
单选题In a three-disk volume group, a disk was physically removed from the system without performing any software procedures to properly remove the disk. Which of the following commands should be performed to recover from this error?()AextendvgBcfgmgrCreducevgDvaryoffvg
单选题A system administrator has a two-disk volume group (testvg) with one logical volume (testlv) which has just been mirrored across both disk drives. Which of the following commands can be used to turn off quorum?()Achvg -Qn testvgBchlv -Qn testlvCvaryoffvg testvg; varyonvg -Qn testvgDvaryoffvg testvg; exportvg testvg; importvg -Qn testvg; varyonvg testvg
单选题A system administrator has determined a root mirrored disk, hdisk1, needs to be replaced. The root volume has been unmirrored. What is the next step to remove the disk drive?()AcfgmgrBrmdev -d hdisk1 -lCreducevg rootvg hdisk1Dhave the IBM CE replace the disk
单选题Which of the following components could MOST likely cause Mike, a technician, to receive a ‘Nonsystem disk or disk error’ after POST?()ABad memoryBVideo cardCFaulty chipsetDFDD
单选题A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()AchvgBrmdevCreducevgDexportvg
单选题Error log analysis indicates that a disk is starting to fail and will need to be replaced. The failing disk contains multiple logical volumes which span multiple disks. A free disk has been added to the failing disk’s volume group.Which of the following is the most efficient method to move the data from the failing disk to the new disk?()ABack up the data, remove the failing disk from the volume group, then restore the data to the new disk.BUse the migratepv command to move data from one disk to another and then remove the failing disk from the volume group.CUse the mirrorvg command to mirror the data to the new disk, break the mirror and then remove the failing disk from the volume group.DCreate a new filesystem on the new disk and use the mv command to move the data to the new filesystem, and then remove the failing disk from the volume group.