单选题Which of the following lists of items all require an HMC to function with POWER5?()ARunning AIX 5.3 Implementing HACMP Implementing Static LPARBImplementing Advanced POWER Virtualization Running Linux Attaching RIO drawersCImplementing VIO Server Implementing Dynamic LPAR Running with SMT turned OnDRunning AIX and Linux on the same system Implementing CoD Implementing Micro-Partitioning

单选题
Which of the following lists of items all require an HMC to function with POWER5?()
A

Running AIX 5.3 Implementing HACMP Implementing Static LPAR

B

Implementing Advanced POWER Virtualization Running Linux Attaching RIO drawers

C

Implementing VIO Server Implementing Dynamic LPAR Running with SMT turned On

D

Running AIX and Linux on the same system Implementing CoD Implementing Micro-Partitioning


参考解析

解析: 暂无解析

相关考题:

In addition to a POWER5 system and an HMC, what else is required to enable Micro-Partitions in an AIX environment?()A、AIX 5.3 and Dynamic Logical PartitioningB、AIX 5.2 and Dynamic Logical PartitioningC、AIX 5.2 and Advanced POWER Virtualization featureD、AIX 5.3 and Advanced POWER Virtualization feature

An administrator is implementing a second server due to the increased usage. Which of the following optimization techniques is the administrator using?()A、Caching enginesB、QoSC、Traffic shapingD、Load balancing

Companycom is installing a p5 595 with AIX 5.3. The DLPAR option for the resources cannot be selected on the HMC menus. However, the daemons are running on both the HMC and LPARs. Which of the following is a prerequisite for DLPAR functionality?()A、The resources must be unallocated in an LPARB、The microcode on the pSeries must be currentC、All network adapters on the LPAR must be definedD、Network connectivity and name resolution capability between HMC and LPARs

During implementation of a two-node cluster,it is determined that error notification for the shared Disk subsystem would be beneficial.  Which of the following is a pre-requisite for implementing automatic error notification?()  A、 The cluster must not be running.B、 The cluster.es.server.utils lpp must be installed.C、 The error notification module must be enabled in RSCT.D、 The permissions on /tmp/hacmp.out need to be changed to 774.

A customer wishes to replace 12 older small UNIX systems.  They are running out of floor space in their data center and any solution must take this into consideration.  Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()A、A p650 running AIX v5.3B、A p5-550 running AIX v5.3C、A p5-570 running Advanced POWER VirtualizationD、Multiple rack-mounted p615s running dynamic LPAR

Which of the following is required to use Simultaneous Multi-Threading (SMT)?()A、smtctl commandB、A dual core chipC、AIX 5.3 operating system and POWER5 hardwareD、Advanced Virtualization which is a separately purchased product

A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()A、p5 hardware, AIX 5.2, Virtual I/O ServerB、POWER4 hardware, AIX 5.3, Virtual I/O Server,C、p5 hardware, AIX 5.3, Advanced POWER Virtualization featureD、POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

An IT director is eager to adopt POWER7 servers because of their relative performance ratings and energy efficiency, but is concerned about migrating applications which require AIX 5.3. Which of the following will address his concern?()A、POWER7 servers running AIX 5.3 operate in POWER5+ mode.B、POWER7 servers running AIX 5.3 operate in POWER6 and POWER6+ mode.C、POWER7 servers running AIX 5.3 operate in POWER5 and POWER6 modes.D、POWER7 servers running AIX 5.3 operate in POWER6 and POWER7 modes.

Companycom currently has three p650 servers in their environment and they are implementing a p5 595. The p650 servers are running in an SMP environment, but are connected to a pair of HMCs. In order to follow best practices in the enterprise server environment and maintain HMC connectivity to the p650s, what else will needs to be ordered in addition to the p5 595?()A、Include a new HMC in the order to connect to the p5 595B、Include a pair of new HMCs in the order to connect to the p5 595C、Include a media set for POWER5 HMC in the order to upgrade one of the existing HMC’s to POWER5 capabilitiesD、Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC to POWER5 capabilities Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC? To POWER5 capabilities

Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()A、Upgrade the p690 to a p5 590 server running AIX 5.3B、Upgrade the p690 server to AIX 5.3 and implement Advanced Power VirtualizationC、Purchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adaptersD、Purchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future.  Which pSeries system would be positioned best to meet this customer’s requirements?()A、p5-550 with the Advanced POWER Virtualization feature and AIX 5.2B、p5-550 with the POWER5 processor technology and AIX 5.2C、p5-570 with the Advanced POWER Virtualization feature and AIX 5.3D、p5-570 with the POWER5 processor technology and AIX 5.2

A customer is implementing a POWER Blade solution which requires the VIO Server to be mirrored on internal disk drives. Which Blade supports the requirement?()A、JS21B、JS23C、PS700D、PS701

Which of the following is the most cost effective required solution to support the boot disks internally for two partitions on a p5-520 running AIX 5.3 without the Advanced Virtualization feature?()A、Optional 4-packB、7311-D20 RIO drawerC、Optional 4-pack and a 7311-D20 RIO drawerD、Optional 4-pack attached to a PCI SCSI card

Which of the following lists of items all require an HMC to function with POWER5?()A、Running AIX 5.3 Implementing HACMP Implementing Static LPARB、Implementing Advanced POWER Virtualization Running Linux Attaching RIO drawersC、Implementing VIO Server Implementing Dynamic LPAR Running with SMT turned "On"D、Running AIX and Linux on the same system Implementing CoD Implementing Micro-Partitioning

单选题Companycom currently has three p650 servers in their environment and they are implementing a p5 595. The p650 servers are running in an SMP environment, but are connected to a pair of HMCs. In order to follow best practices in the enterprise server environment and maintain HMC connectivity to the p650s, what else will needs to be ordered in addition to the p5 595?()AInclude a new HMC in the order to connect to the p5 595BInclude a pair of new HMCs in the order to connect to the p5 595CInclude a media set for POWER5 HMC in the order to upgrade one of the existing HMC’s to POWER5 capabilitiesDInclude a media set for POWER5 HMC in the order to upgrade both of the existing HMC to POWER5 capabilities Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC? To POWER5 capabilities

单选题A customer is implementing a POWER Blade solution which requires the VIO Server to be mirrored on internal disk drives. Which Blade supports the requirement?()AJS21BJS23CPS700DPS701

单选题During implementation of a two-node cluster,it is determined that error notification for the shared Disk subsystem would be beneficial.  Which of the following is a pre-requisite for implementing automatic error notification?()A The cluster must not be running.B The cluster.es.server.utils lpp must be installed.C The error notification module must be enabled in RSCT.D The permissions on /tmp/hacmp.out need to be changed to 774.

单选题A customer wishes to replace 12 older small UNIX systems.  They are running out of floor space in their data center and any solution must take this into consideration.  Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()AA p650 running AIX v5.3BA p5-550 running AIX v5.3CA p5-570 running Advanced POWER VirtualizationDMultiple rack-mounted p615s running dynamic LPAR

单选题A customer is in the initial stages of implementing a server consolidation project.  The Information Technology staff has identified several Microsoft Windows servers that are running single applications on older hardware and averaging under 20% utilization.  Part of their server consolidation goal is to lower the number of servers, decrease the operating system license cost, and increase utilization per server.  Which of the following IBM Director extensions could be used to satisfy all of these requirements?()AAurema Application Workload ManagerBRemote Deployment ManagerCVirtual Machine ManagerDCapacity Manager

单选题A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()Ap5 hardware, AIX 5.2, Virtual I/O ServerBPOWER4 hardware, AIX 5.3, Virtual I/O Server,Cp5 hardware, AIX 5.3, Advanced POWER Virtualization featureDPOWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

单选题An IT director is eager to adopt POWER7 servers because of their relative performance ratings and energy efficiency, but is concerned about migrating applications which require AIX 5.3. Which of the following will address his concern?()APOWER7 servers running AIX 5.3 operate in POWER5+ mode.BPOWER7 servers running AIX 5.3 operate in POWER6 and POWER6+ mode.CPOWER7 servers running AIX 5.3 operate in POWER5 and POWER6 modes.DPOWER7 servers running AIX 5.3 operate in POWER6 and POWER7 modes.

单选题In addition to a POWER5 system and an HMC, what else is required to enable Micro-Partitions in an AIX environment?()AAIX 5.3 and Dynamic Logical PartitioningBAIX 5.2 and Dynamic Logical PartitioningCAIX 5.2 and Advanced POWER Virtualization featureDAIX 5.3 and Advanced POWER Virtualization feature

单选题What is a limitation of implementing uRPF?()AMPLS LDP must be enabled.BBGP routing protocol must be running.CNamed access-lists must be configured.DSymmetrical routing is required.EDomain name must be defined

单选题An administrator is implementing a second server due to the increased usage. Which of the following optimization techniques is the administrator using?()ACaching enginesBQoSCTraffic shapingDLoad balancing

单选题Which of the following lists of items all require an HMC to function with POWER5?()ARunning AIX 5.3 Implementing HACMP Implementing Static LPARBImplementing Advanced POWER Virtualization Running Linux Attaching RIO drawersCImplementing VIO Server Implementing Dynamic LPAR Running with SMT turned OnDRunning AIX and Linux on the same system Implementing CoD Implementing Micro-Partitioning

单选题Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()AUpgrade the p690 to a p5 590 server running AIX 5.3BUpgrade the p690 server to AIX 5.3 and implement Advanced Power VirtualizationCPurchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adaptersDPurchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

单选题A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future.  Which pSeries system would be positioned best to meet this customer’s requirements?()Ap5-550 with the Advanced POWER Virtualization feature and AIX 5.2Bp5-550 with the POWER5 processor technology and AIX 5.2Cp5-570 with the Advanced POWER Virtualization feature and AIX 5.3Dp5-570 with the POWER5 processor technology and AIX 5.2

单选题Which of the following is the most cost effective required solution to support the boot disks internally for two partitions on a p5-520 running AIX 5.3 without the Advanced Virtualization feature?()AOptional 4-packB7311-D20 RIO drawerCOptional 4-pack and a 7311-D20 RIO drawerDOptional 4-pack attached to a PCI SCSI card