单选题Fuel oil tank vents are fitted with a screen which will stop().Aoil from flowing out of the tank ventBair from entering the tank ventCvapors from leaving the tank ventDflames on deck from entering the tank vent

单选题
Fuel oil tank vents are fitted with a screen which will stop().
A

oil from flowing out of the tank vent

B

air from entering the tank vent

C

vapors from leaving the tank vent

D

flames on deck from entering the tank vent


参考解析

解析: 暂无解析

相关考题:

The main propulsion diesel continues running after you try to shut down. You should now attempt to .A.stop the fuel oil booster pumpB.engage the jacking gearC.secure the lube oil pumpD.shut off the fuel at the settling tank

During UMS rounds, a duty engineer notices that the fuel oil overflow observation glass is full of oil. Should he ____.A.Stop all F.O. transfers immediately, and inform the chief engineer.B.Make a sounding of the F.O. overflow tank and decide if there is enough capacity to leave it until the following morning.C.Call a motorman and have him sound the F.O. overflow tank periodically during the night.D.start the F.O. purifier

Every new crude oil tanker of 20 000 tons deadweight and above shall be fitted with a cargo tank cleaning system using ______.A.Hot waterB.Cold waterC.ChemicalsD.Crude oil washing

Gasoline fuel tank vents should terminate ______.A.In the engine compartmentB.In the fuel tank spaceC.Above or outside the hullD.At the most convenient location

材料:Every new crude oil tanker of 20000 tons deadweight and above shall be fitted with a cargo tank cleaning system using crude oil washing.The Administration shall undertake to ensure that the system fully complies with the requirements of MARPOL within one year after the tanker was first engaged in the trade of carrying crude oil or by the end of the third voyage carrying crude oil suitable for crude oil washing,whichever occurs later.Unless such oil tanker carries crude oil which is not suitable for crude oil washing,the oil tanker shall operate the system in accordance with the requirements of that Regulation.Every existing crude oil tanker of 40000 tons deadweight and above shall be provided with segregated ballast tanks.Existing crude oil tankers may,in lieu of being provided with segregated ballast tanks,operate with a cargo tank cleaning procedure using crude oil washing unless the crude oil tanker is intended to carry crude oil which is not suitable for crude oil washing.Existing crude oil tankers may,in lieu of being provided with segregated ballast tanks or operating with a cargo tank cleaning procedure using crude oil washing,operate with dedicated clean ballast tanks in accordance with the provision of Regulation 13A of this Annex for the following period:for crude oil tankers of 70 000 tons deadweight and above,until two years after the date of entry into force of the present Convention;and for crude oil tankers of 40000 tons deadweight and above but below 70 000 tons deadweight,until four years after the date of entry into force of the present Convention.问题:A new crude oil tanker of 30000 tons deadweight shall ________.A.be fitted with crude oil washing systemB.operate dedicated clean ballast tanksC.be fitted with segregated ballast tanksD.be fitted with washing system other than crude oil washing systemExcept________,the existing crude oil tankers may operate with any of the following installations.A.segregated ballast tanksB.cargo tank cleaning procedure using crude oil washingC.operate with dedicated clean ballast tanksD.protection positionThe latest date for an existing crude oil tanker of 60000 tons deadweight to install dedicated clean ballast tanks is ________.A.until two years after the date of entry into force of the present ConventionB.until four years after the date of entry into force of the present ConventionC.within one year after the tanker was first engaged in the trade of carrying crude oilD.by the end of the third voyage carrying crude oilIt is inferred that ________.A.all oil tankers,both the newly built and existing ones,shall be fitted with a cargo tank cleaning system using crude oil washingB.a new crude oil tanker of 20 000 tons deadweight and above may,in lieu of being provided with crude oil washing system,operate with segregated ballast tanksC.a new crude oil tanker of 20 000 tons deadweight and above may,in lieu of being provided with crude oil washing system,operate with dedicated clean ballast tanksD.a new crude oil tanker of 20 000 tons deadweight and above shall not be fitted with a cargo tank cleaning system using crude oil washing immediately after her entry in the trade of carrying crude oil请帮忙给出每个问题的正确答案和分析,谢谢!

单选题In a commonly used fuel oil system, the oil is stored in tanks in the double bottom from which it is pumped to () and heated.Aa service tankBa settling tankCan expansion tankDa double bottom tank

单选题If the overflow tank high-level alarm sounds while the fuel oil tanks are being topped off, the engineer should ().Aclose the static leg filling valveBclose the overflow tank falling valveCreduce the fuel oil pumping rateDstop the fuel oil pumping operation

单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()Acold fuel oilBlow fuel oil pressureClow atomizing steam pressureDwater in the fuel oil

单选题When you are transferring fuel oil to the setting tanks, precautions to be observed should include ()Aplugging gooseneck tank vents to prevent accident overflowBmaintaining a high transfer rate until a slight trickle of oil is observed flowing from the overflow lineCsounding the tanks frequently and reducing the transfer rate as the level approaches maximum fillDmaintaining a supply of chemical dispersant to cleanup minor oil spills adjacent to the ship

单选题In a typical fuel oil system, the oil is stored in tanks in the double bottom from which it is pumped to () and heated.Aa service tankBa collecting tankCa sumpDa settling tank

单选题A dirty fuel oil filter element can be detected by ()AVisual inspection of the elementBthe pressure drop cross the filterChigh fuel oil tank temperatureDincrease flow rate from the filter

单选题The depth of fuel oil in a tank is normally measured through the()Avent lineBoverflow lineCfeed lineDsounding tube

单选题Your vessel has run aground and upon taking fuel oil tank soundings, you find that a fuel tank level has increasedYou therefore should suspect ().Acondensation in the fuel tankBa crack in the hull portion of the fuel tankCa load of bad fuelDcontamination from the saltwater flushing system

单选题Every new crude oil tanker of 20000 tons deadweight and above shall be fitted with a cargo tank cleaning system using().Ahot waterBcold waterCchemicalsDcrude oil washing

单选题To receive oil residues from the purification of fuel and lubricating oils in the machinery spaces, what kind of tank(s) should be provided on board?()Abilge tankBsludge tankCoverflow tankDoil collecting tank

单选题Fire protection regulations for towing vessels require any fuel line subject to internal head pressure from fuel in the tank to().Abe fitted with a positive fuel shut-off valve located at the tankBhave a shut-off valve at the top of the tankChave a gate valve easily accessible in the space where the tank is locatedDhave a drain cock at the lowest point in the fuel line

单选题Which of the actions listed should be taken FIRST to control an oil fire in a fuel oil tank?()ACommence draining that tank as quickly as possibleBSeal off all vents to that tankCActivate the CO2 system to that tankDShut off the steam heating coils

单选题Which of the followings will affect the spray of fuel oil?()Acoke depositsBcylinder water temperatureCasphalt in fuel oilDlub oil

单选题The pollution prevention regulations do not apply to the transfer or discharge of ()Abunker fuel for use aboard shipBlubricating oil for use aboard shipCcoconut oil carried in tank vesselsDoily water from a ships bilges

单选题The () or balance tank collects the re-circulated fuel oil.AbufferBsumpCbilgeDoverflowing

单选题Thermostatic steam pressure reducing valves are used in the fuel oil service system to control the()Adouble bottom fuel oil tank temperatureBheater supply steam flowCpressure of the fuel supplied to the burnersDattemperator steam flow in the heater discharge circuit

单选题Machinery driving fuel oil transfer and fuel oil service pumps must be fitted with a remote means of stopping the machinery from ().Awithin the space concernedBoutside the space concernedCthe throttle stationDwithin the fire room

单选题Following a grounding, you can best determine that a SLACK fuel oil tank has been holed by ().Asounding the tankBwaiting for the vessel to listCexamining tank boundariesDchecking fuel oil strainers

单选题Permitting a diesel engine fuel oil day tank to run dry can cause ()Aoverheated injection pumpsBwater condensation in the cylindersCfuel dilution of the lube oilDair in the fuel system

单选题The amount of expansion space to be left in a fuel tank when fuel oil is being received, is determined by the ().Aquantity of fuel to be receivedBflash point of the fuel as it is receivedCfuel temperature as it is receivedDviscosity of the fuel being received

单选题Gasoline fuel tank vents should terminate().Ain the engine compartmentBin the fuel tank spaceCabove or outside the hullDat the most convenient location

单选题Every()shall be fitted with a cargo tank cleaning system using crude oil washing.Aexisting crude oil tanker of 20000 tons deadweight and underBnew crude oil tanker of 20000 tons deadweight and underCexisting crude oil tanker of 20000 tons deadweight and aboveDnew crude oil tanker of 20000 tons deadweight and above