单选题During reboot, the system hangs with an LED 0554 message that means, "The boot device could not be opened or a read failed."  Which of the following recovery procedures should be taken ()ABoot in maintenance mode and use fsck to check hd5.BBoot in maintenance mode, access the rootvg and check the /etc/inittab for corruption.CBoot in maintenance mode, access the rootvg and rebuild the boot image using the bosboot command.DBoot in maintenance mode, and reset the root password.

单选题
During reboot, the system hangs with an LED 0554 message that means, "The boot device could not be opened or a read failed."  Which of the following recovery procedures should be taken ()
A

Boot in maintenance mode and use fsck to check hd5.

B

Boot in maintenance mode, access the rootvg and check the /etc/inittab for corruption.

C

Boot in maintenance mode, access the rootvg and rebuild the boot image using the bosboot command.

D

Boot in maintenance mode, and reset the root password.


参考解析

解析: 暂无解析

相关考题:

A system powers on, begins POST, displays the BIOS version information and then hangs with the error message ‘Error loading operating system’. Which of the following is MOST likely the cause of this issue? ()A. A virus has infected the systemB. Corrupted BOOT.INI fileC. Corrupt MBRD. Boot sector corruption

A technician is dispatched to a malware infected system. Upon arrival, the technician notices themalware’s pop-up on the screen. Which of the following boot methods would the technician utilize?() A. Reboot in Safe ModeB. Reboot in Recovery ConsoleC. Reboot in Last Known Good ConfigurationD. Reboot in System Debug Mode

AIX 5L and SUN Solaris have differing approaches at handling processor failures. Which statement best describes how AIX handles processor failures?()A、If AIX discovers a processor with too many recoverable errors during runtime, it will dynamically turn off that processor, while the rest of the system keeps running.B、If AIX detects a failing processor it will automatically move all resources to another processor. The failed processor can be hot-swapped and the new replacement becomes the active processor.C、If AIX determines a processor is failing, it will perform diagnostics to determine which processor function can be disabled and dynamically reallocate all CPU and memory resources thus isolating the failure condition and preventing a reboot.D、If AIX senses a processor level error condition, internal diagnostics are activated to determine the severity of the problem. After the failure threshold is met, a message is broadcast to the service processor informing the operator to perform a system reboot.

During a system administrator attempt to boot a server in normal mode, the boot process displays LED 299 and Led 201 and then stops. The LED 201 indicates that a ROS init or checkstop was detected. Which of the following options is the most probable cause?()A、A corrupted JFS log deviceB、A corrupted boot logical volumeC、An incorrect rc.boot entry in /etc/inittab fileD、A problem initializing paging space

A system powers on, begins POST, displays the BIOS version information and then hangs with the error message ‘Error loading operating system’. Which of the following is MOST likely the cause of this issue? ()A、A virus has infected the systemB、Corrupted BOOT.INI fileC、Corrupt MBRD、Boot sector corruption

A system powers on, begins POST, displays the BIOS version information and then hangs with the error message Error loading operating system. Which of the following is MOST likely cause of this issue? ()A、A virus has infected the systemB、Corrupted BOOT.INI fileC、Corrupt MBRD、Boot sector corruption

A technician is dispatched to a malware infected system. Upon arrival, the technician notices themalware’s pop-up on the screen. Which of the following boot methods would the technician utilize?()A、Reboot in Safe ModeB、Reboot in Recovery ConsoleC、Reboot in Last Known Good ConfigurationD、Reboot in System Debug Mode

A system must be upgraded from AIX 5.1 to 5.2.  Which of the following scheduling processes should be performed? ()A、 Schedule enough down time to backup, upgrade and reboot. B、 Backup, upgrade, then schedule enough down time to reboot the system. C、 Backup, then schedule enough down time to upgrade and reboot the system. D、 No scheduling processes are necessary because no down time is required.

During system boot, rootvg fails to vary on, causing an LED code of 0552. What is the most likely cause for rootvg not varying on?()A、Missing blvB、Network problemC、Wrong boot tableD、Corrupted file system

During system boot, the system hangs at LED 0C31. What is the first step the system administrator should take to correct the problem?()A、Check system console connectionsB、Check system network connectionsC、Boot in service mode and change the bootlistD、Boot from the AIX installation media and mount rootvg filesystems

A system dump has occured. The LED display shows 0c0. What does this indicate?()A、The dump was successful.B、A system dump is in progress.C、No system dump device configured.D、There was an I/O error during the dump.

An LPAR has hung during a reboot, reporting a 0552LED code. What does this signify?()A、varyon of the paging device failed.B、fsck of the root (/) filesystem failed.C、varyon of the root volume group failed.D、IPL device could not be opened or a read failed.

A system administrator needs to quickly migrate a machine from AIX 5.1 to AIX 5.2. The administrator will only be allowed enough downtime to reboot the machine. Which installation method should be used to accomplish this task?()A、Perform a migration installation during the reboot process.B、Perform an alternate disk installation and migration using NIM.C、Copy the /usr directory from another 5.2 server to this server.D、Perform an update_all install from 5.2 media to take effect on reboot.

A system was running properly until a reboot. Following the reboot, the system LED displayed cycles between 0223 and 0229. Which of the following procedures should be performed next?()A、Power down then power up the systemB、Boot into diagnostic mode and run fsckC、Boot from installation media and run bosbootD、Boot into maintenance mode and check the bootlist

A system administrator needs to upgrade the Oracle database from Version 7 to Version 8.  Which of the following scheduling concerns should be considered?()A、Schedule enough down time to backup, upgrade and reboot. B、Backup, upgrade, then schedule enough down time to reboot the system.C、Backup, then schedule enough down time to upgrade and reboot the system. D、There are no scheduling concerns because no down time is required.

An LPAR has hung during a reboot, reporting a 0552 LED code. What does this signify?()A、varyon of the paging device failed.B、fsck of the root (/) filesystem failed.C、varyon of the root volume group failed.D、IPL device could not be opened or a read failed.

During system boot, the boot process hangs at LED 0551.  Which of the following is a likely cause()A、A network problemB、corrupted filesystemC、corrupted ODMD、corrupted /etc/inittab file

During reboot the system hangs with an LED 0554 message that means, "The boot device could not be opened or a read failed." What recovery procedures should be taken?()A、Boot in maintenance and use fsck to check hd5.B、Boot in maintenance mode, access the rootvg and check the /etc/inittab for corruption.C、Boot in maintenance mode, access the rootvg and rebuild the boot image using the bosboot command.D、Boot in maintenance mode, access the rootvg and use the bootlist command to create a valid boot list.

A System p administrator needs to upgrade a system from AIX 5.2 to AIX 5.3.  Which of the following installation methods would minimize downtime()A、Migration installationB、Partition MobilityC、alt_disk_installD、update_all smit fastpath and reboot during the next scheduled outage

An administrator needs to change a system’s run level from level 2 to level 3. What is the appropriate  method to accomplish this()A、Use the reboot command.B、Edit the /etc/reboot file and reboot the system.C、Edit /etc/.init.state file and reboot the system.D、Use the telinit command

单选题A System p administrator needs to upgrade a system from AIX 5.2 to AIX 5.3.  Which of the following installation methods would minimize downtime()AMigration installationBPartition MobilityCalt_disk_installDupdate_all smit fastpath and reboot during the next scheduled outage

单选题During reboot the system hangs with LED 0581 that indicates "Configuring TCP/IP." Which recovery procedures should be taken?()ABoot in maintenance mode, and verify the Ethernet adapter configuration.BBoot in maintenance mode, access the rootvg and check the /etc/inittab for corruption.CBoot in maintenance mode, access the rootvg and rebuild the boot image using the bosboot command.DBoot in maintenance mode after verifying the network connection, access the rootvg and check the /etc/rc.net file.

单选题During system boot, the boot process hangs at LED 0551.  Which of the following is a likely cause()AA network problemBcorrupted filesystemCcorrupted ODMDcorrupted /etc/inittab file

单选题During a system administrator attempt to boot a server in normal mode, the boot process displays LED 299 and Led 201 and then stops. The LED 201 indicates that a ROS init or checkstop was detected. Which of the following options is the most probable cause?()AA corrupted JFS log deviceBA corrupted boot logical volumeCAn incorrect rc.boot entry in /etc/inittab fileDA problem initializing paging space

单选题A graphics card has been added to the system. After rebooting, the system hangs during the login process with a blue screen indicating "CDE please wait". Which of the following procedures should be performed next?()AReinstall the CDE softwareBCheck the name resolutionCUncomment the last line in .dtprofileDBoot in maintenance mode and perform fsck on file systems

单选题A system powers on, begins POST, displays the BIOS version information and then hangs with the error message Error loading operating system. Which of the following is MOST likely cause of this issue? ()AA virus has infected the systemBCorrupted BOOT.INI fileCCorrupt MBRDBoot sector corruption

单选题A system dump has occured. The LED display shows 0c0. What does this indicate?()AThe dump was successful.BA system dump is in progress.CNo system dump device configured.DThere was an I/O error during the dump.