单选题A two-node cluster is attached via SAN to shared disk. The customer has requested that one of the nodes be moved to another room 300 feet away. However, this distance exceeds the length specified by the RS232 specifications. What solution would resolve the RS232 specification issue with the fewest additional components?()A Target mode fiber channel can be used with a SAN solution.B The heartbeat could be established by using a disk heartbeat.C An RS232 line driver can be used to extend the existing serial connection.D The NIM for the serial connection can be altered to compensate for the additional delay caused by the increased distance.
单选题
A two-node cluster is attached via SAN to shared disk. The customer has requested that one of the nodes be moved to another room 300 feet away. However, this distance exceeds the length specified by the RS232 specifications. What solution would resolve the RS232 specification issue with the fewest additional components?()
A
Target mode fiber channel can be used with a SAN solution.
B
The heartbeat could be established by using a disk heartbeat.
C
An RS232 line driver can be used to extend the existing serial connection.
D
The NIM for the serial connection can be altered to compensate for the additional delay caused by the increased distance.
参考解析
解析:
暂无解析
相关考题:
An SMB customer requires a tower server with 2TB of internal storage. The customer has requested a low cost solution. What IBM System x server would satisfy this criteria?()A、x3250B、x3200C、x3650D、x3400
A two-node cluster is attached via SAN to shared disk. The customer has requested that one of the nodes be moved to another room 300 feet away. However, this distance exceeds the length specified by the RS232 specifications. What solution would resolve the RS232 specification issue with the fewest additional components?()A、 Target mode fiber channel can be used with a SAN solution.B、 The heartbeat could be established by using a disk heartbeat.C、 An RS232 line driver can be used to extend the existing serial connection.D、 The NIM for the serial connection can be altered to compensate for the additional delay caused by the increased distance.
A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated. The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage. Each system has the following: ? 2 integrated network ports ? 2 fibre channel adapter cards ? 1 power supply and redundant cooling ? HACMP v5.1 In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()A、One fibre channel switchB、Two fibre channel switchesC、Two Ethernet cardsD、Nothing
A client has requested an IBM System x solution. Pricing is the most sensitive decision factor. They are looking for 12 TB of storage, with a projected growth of 10-15%. As this is the only server accessing this amount of data, the customer does not require a SAN. What should the System x Sales Specialist recommend?()A、A DS3000 iSCSI-based solution.B、One MegaRAID 8480 card with 4 EXP3000 units.C、An N3700 network attached solution.D、A DS6000 Fibre Channel solution with EXP710 expansion units.
A customer synchronizes the cluster in a virtualized environment. During the process the following warning isdisplayed: "For nodes with a single Network Interface Card per logical network configured, it is recommended to includethe file ’/usr/es/sbin/cluster/netmon.cf’ with a pingable IP address as described in the PowerHA PlanningGuide". What should the customer do next?()A、Ignore the warning as synchronization completed successfully.B、Populate the /usr/es/sbin/cluster/netmon.cf file with one or many IP addresses external to the cluster.C、Create another virtual adapter on each node and set-up PowerHA networking in a more traditional fashionD、Populate the /usr/es/sbin/cluster/netmon.cf file with any of the boot IP addresses on one of the othercluster nodes
A customer has two single cluster IBM TS7700 Virtualization Engines at the same site. The customer wants to move one to a remote site and set up a grid configuration with the two clusters. The customer has fibre between the two sites. What is the most important factor to consider when planning the new configuration?()A、operator trainingB、cache size of the two clustersC、fibre bandwidth capability between the sitesD、number of stacked tape drives attached to each cluster
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()A、What are the plans for Disaster Recovery? B、What are the plans for data migration? C、Would iSCSI meet your needs? D、How much space is available in the current storage systems?
A customer has been working with your company to purchase an iDataPlex cluster. They have a configuration from IBM and are getting ready to place an order. Which should be done of the following?()A、A solution sizing questionnaireB、Verify the customer has the proper racksC、A Technical Delivery AssessmentD、Verify the customer has enough cooling in the computer room
A cluster administrator has been asked to install HACMP on two nodes with the following hardware: -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage. In order to eliminate single points of failure,the administrator should first add which of the following:() A、 an additional 1GB RAM to each node.B、 Another bootable mirrored disk drive.C、 A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D、 Nothing,because this is a viable cluster solution with no single points of failure.
The user base of a three-node cluster has increased. In order to add clustered users to all nodes, which of the following steps should be performed?() A、 On one of the nodes,add the users via C-SPOC ’Add a User to the Cluster’smit menu.B、 Use C-SPOC to synchronize the password files between cluster nodes.C、 On all of the nodes,add the users to the /etc/passwd and system security files,and then synchronize the cluster.D、 On one of the nodes,add the users to the /tec/passwd and system security files,add home directories,and use cron to automate the movement of system security files between nodes.
Company.com environment consists of 10 volume groups and 4 physical networks. The customer Desires the fastest possible fallover for a two-node cluster. Which of the following configuration alternatives will provide the fastest fallover?() A、 IPAT via IP Aliasing,default shared volume groupsB、 IPAT via IP Replacement default shared volume groupsC、 IPAT via IP Aliasing,enhanced concurrent volume groupsD、 IPAT via IP Replacement,enhanced concurrent volume groups
An administrator has a two-node PowerHA cluster in a mutual takeover configuration. He needs to updatefrom 5.5 service pack 1 to 5.5 service pack 2. Which of the following actions will perform the updates with norisk of disruption to applications running in the cluster?()A、Unmanage resource groups on all nodes, update the cluster filesets, start cluster services on all nodes,ensure cluster services stabilizeB、Update the cluster filesets on all nodes. Run ’refresh -s clstrmgrES’ on one node, wait for the cluster tostabilize, repeat for all other nodesC、Unmanage resource groups on one node, update the cluster filesets, start cluster services. Wait for thecluster to stabilize and repeat for all other nodes.D、Bring resource groups (RGs) online on all nodes concurrently, bring RGs offline on one node, update thecluster filesets, bring RGs online, repeat for all other nodes
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()A、What are Disaster RecoveryplansB、What are plans for datamigrationC、What storage system space isavailableD、DoesiSCSI meet the needs
You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()A、Two child partitions with volumes mounted from an iSCSI SANB、Two host servers with Fibre Channel-attached storage enabled for Cluster Shared Volumes (CSVs)C、Two host servers with iSCSI-attached storage enabled for Cluster Shared Volumes (CSVs)D、Two child partitions with VHDs stored on an iSCSI SAN
单选题A customer synchronizes the cluster in a virtualized environment. During the process the following warning isdisplayed: "For nodes with a single Network Interface Card per logical network configured, it is recommended to includethe file ’/usr/es/sbin/cluster/netmon.cf’ with a pingable IP address as described in the PowerHA PlanningGuide". What should the customer do next?()AIgnore the warning as synchronization completed successfully.BPopulate the /usr/es/sbin/cluster/netmon.cf file with one or many IP addresses external to the cluster.CCreate another virtual adapter on each node and set-up PowerHA networking in a more traditional fashionDPopulate the /usr/es/sbin/cluster/netmon.cf file with any of the boot IP addresses on one of the othercluster nodes
单选题During a planning session, the customer indicates that they intend to build two independent two- Node clusters (cluster ’A’ and ’B’) that will be provided shared storage form an IBM TotalStorage FAStT900 server. The customer intends to present 2 LUNs to cluster ’A’, and 2 LUNs to cluster ’B’. All hosts will be dual attached via fibre. What additional hardware or software is necessary to make this a valid configuration?()A SAN switchesB Fibre channel Hub(s)C IBM Storage Manager AgentsD IBM Subsystem Device Driver
单选题A cluster administrator has been asked to install HACMP on two nodes with the following hardware: -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage. In order to eliminate single points of failure,the administrator should first add which of the following:()A an additional 1GB RAM to each node.B Another bootable mirrored disk drive.C A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.D Nothing,because this is a viable cluster solution with no single points of failure.
单选题A customer is interested in using two Power 550 servers to implement a new two node cluster. The cluster willbe using SAN attached disk for shared storage and will be attached to one IP network. Which of the followingadapter configurations will meet the customer requirements while reducing single points of failure?()A AB BC CD D
单选题A client has requested an IBM System x solution. Pricing is the most sensitive decision factor. They are looking for 12 TB of storage, with a projected growth of 10-15%. As this is the only server accessing this amount of data, the customer does not require a SAN. What should the System x Sales Specialist recommend?()AA DS3000 iSCSI-based solution.BOne MegaRAID 8480 card with 4 EXP3000 units.CAn N3700 network attached solution.DA DS6000 Fibre Channel solution with EXP710 expansion units.
单选题An SMB customer requires a tower server with 2TB of internal storage. The customer has requested a low cost solution. What IBM System x server would satisfy this criteria?()Ax3250Bx3200Cx3650Dx3400
单选题A customer has a requirement for a storage solution that meets the following criteria: (1)Heterogeneous hosts attached (2)Support for block I/O (3)High Speed (4)Scalable Which solution would satisfy the customer’s requirement?()ASANBNASCSCSIDiSCSI
单选题A customer has two single cluster IBM TS7700 Virtualization Engines at the same site. The customer wants to move one to a remote site and set up a grid configuration with the two clusters. The customer has fibre between the two sites. What is the most important factor to consider when planning the new configuration?()Aoperator trainingBcache size of the two clustersCfibre bandwidth capability between the sitesDnumber of stacked tape drives attached to each cluster
单选题A customer has been working with your company to purchase an iDataPlex cluster. They have a configuration from IBM and are getting ready to place an order. Which should be done of the following?()AA solution sizing questionnaireBVerify the customer has the proper racksCA Technical Delivery AssessmentDVerify the customer has enough cooling in the computer room
单选题An administrator has a two-node PowerHA cluster in a mutual takeover configuration. He needs to updatefrom 5.5 service pack 1 to 5.5 service pack 2. Which of the following actions will perform the updates with norisk of disruption to applications running in the cluster?()AUnmanage resource groups on all nodes, update the cluster filesets, start cluster services on all nodes,ensure cluster services stabilizeBUpdate the cluster filesets on all nodes. Run ’refresh -s clstrmgrES’ on one node, wait for the cluster tostabilize, repeat for all other nodesCUnmanage resource groups on one node, update the cluster filesets, start cluster services. Wait for thecluster to stabilize and repeat for all other nodes.DBring resource groups (RGs) online on all nodes concurrently, bring RGs offline on one node, update thecluster filesets, bring RGs online, repeat for all other nodes
单选题Company.com environment consists of 10 volume groups and 4 physical networks. The customer Desires the fastest possible fallover for a two-node cluster. Which of the following configuration alternatives will provide the fastest fallover?()A IPAT via IP Aliasing,default shared volume groupsB IPAT via IP Replacement default shared volume groupsC IPAT via IP Aliasing,enhanced concurrent volume groupsD IPAT via IP Replacement,enhanced concurrent volume groups
单选题You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()ATwo child partitions with volumes mounted from an iSCSI SANBTwo host servers with Fibre Channel-attached storage enabled for Cluster Shared Volumes (CSVs)CTwo host servers with iSCSI-attached storage enabled for Cluster Shared Volumes (CSVs)DTwo child partitions with VHDs stored on an iSCSI SAN
单选题The user base of a three-node cluster has increased. In order to add clustered users to all nodes, which of the following steps should be performed?()A On one of the nodes,add the users via C-SPOC ’Add a User to the Cluster’smit menu.B Use C-SPOC to synchronize the password files between cluster nodes.C On all of the nodes,add the users to the /etc/passwd and system security files,and then synchronize the cluster.D On one of the nodes,add the users to the /tec/passwd and system security files,add home directories,and use cron to automate the movement of system security files between nodes.